2006
DOI: 10.1161/01.res.0000249531.23654.e1
|View full text |Cite
|
Sign up to set email alerts
|

Time Course of Degradation of Cardiac Troponin I in Patients With Acute ST-Elevation Myocardial Infarction

Abstract: Abstract-Although measurement of troponin is widely used for diagnosing acute myocardial infarction (AMI), its diagnostic potential may be increased by a more complete characterization of its molecular appearance and degradation in the blood. The aim of this study was to define the time course of cardiac troponin I (cTnI) degradation in patients with acute ST-elevation myocardial infarction (STEMI). In the ASSENT-2 substudy, 26 males hospitalized with STEMI were randomized to 2 different thrombolytic drugs wit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
43
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 50 publications
(44 citation statements)
references
References 21 publications
1
43
0
Order By: Relevance
“…The purified cTn ITC used in this assay was obtained from heart tissue from individuals diagnosed with heart failure, suggesting a possible difference in the intrinsic pathological degradations between tissue from patients with different heart diseases (ischemia vs heart failure) and those present in serum before or during the purification process. This N-terminal degradation was also phosphorylation dependent (5E6 detected both bands whereas 22B11 detected only the upper band), consistent with previous findings (9,14 ). Ultimately, it is only through analysis of larger numbers of individual samples that this seeming ambiguity in terminal degradation will be sorted out.…”
Section: Discussionsupporting
confidence: 90%
See 2 more Smart Citations
“…The purified cTn ITC used in this assay was obtained from heart tissue from individuals diagnosed with heart failure, suggesting a possible difference in the intrinsic pathological degradations between tissue from patients with different heart diseases (ischemia vs heart failure) and those present in serum before or during the purification process. This N-terminal degradation was also phosphorylation dependent (5E6 detected both bands whereas 22B11 detected only the upper band), consistent with previous findings (9,14 ). Ultimately, it is only through analysis of larger numbers of individual samples that this seeming ambiguity in terminal degradation will be sorted out.…”
Section: Discussionsupporting
confidence: 90%
“…Although the C-terminus of cTnI is proposed to be degraded first in myocardium from patients undergoing coronary bypass surgery (10 ) and in isolated rat hearts undergoing ischemia (9,24 ), and has been detected in the blood of MI patients (11,14 ), the N-terminal degradation product has also been observed (11,13,38 ). The purified cTn ITC used in this assay was obtained from heart tissue from individuals diagnosed with heart failure, suggesting a possible difference in the intrinsic pathological degradations between tissue from patients with different heart diseases (ischemia vs heart failure) and those present in serum before or during the purification process.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The N-terminal degradation of cardiac TnI was reported in a tail suspension rat model that simulated microgravity [34]. More interestingly, several groups have reported degradation products of TnI in serum of patients after acute myocardial infarction (AMI) [35][36][37]. Degradation products of TnT were also found both in animal models of ischemia/reperfusion injury [38,39] and in serum of patients with AMI [40,41].…”
Section: Degradationmentioning
confidence: 99%
“…Protein degradation often involves significant molecular weight (MW) reduction, which can be readily detected by 1-D-gel separation followed by Western blot analysis [31,32,[34][35][36][37][38][39][40][41]. Comparative 2-DE was also used to study proteomic changes on a broader scale, and PMF can be employed to identify changed proteins [46].…”
Section: Degradationmentioning
confidence: 99%