2011
DOI: 10.1002/mrm.23081
|View full text |Cite
|
Sign up to set email alerts
|

Time‐interleaved acquisition of modes: An analysis of SAR and image contrast implications

Abstract: As the magnetic field strength and therefore the operational frequency in MRI are increased, the radiofrequency wavelength approaches the size of the human head/body, resulting in wave effects which cause signal decreases and dropouts. Especially, whole-body imaging at 7 T and higher is therefore challenging. Recently, an acquisition scheme called timeinterleaved acquisition of modes has been proposed to tackle the inhomogeneity problems in high-field MRI. The basic premise is to excite two (or more) different… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
55
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(55 citation statements)
references
References 13 publications
0
55
0
Order By: Relevance
“…By forming virtual receive elements, both images were reconstructed together as a 32-channel data set using the generalized autocalibrating partially parallel acquisitions (GRAPPA) algorithm to achieve a more homogeneous image. 30,31 For MR imaging of the lower extremity vessels, a 2D nonenhanced T1-weighted spoiled gradient echo sequence (FLASH) was acquired with and without a venous saturation pulse. Both sequence types were acquired consecutively for each imaging station before the AngioSURF table was moved to the subsequent station.…”
Section: Sequence Protocolmentioning
confidence: 99%
“…By forming virtual receive elements, both images were reconstructed together as a 32-channel data set using the generalized autocalibrating partially parallel acquisitions (GRAPPA) algorithm to achieve a more homogeneous image. 30,31 For MR imaging of the lower extremity vessels, a 2D nonenhanced T1-weighted spoiled gradient echo sequence (FLASH) was acquired with and without a venous saturation pulse. Both sequence types were acquired consecutively for each imaging station before the AngioSURF table was moved to the subsequent station.…”
Section: Sequence Protocolmentioning
confidence: 99%
“…In those volunteers where the aforementioned problem was encountered, dedicated TIAMO shims [16] were calculated based on acquired B 1 + maps in the same imaging position. The two shims were calculated to adjust the phases of the 8 transmit channels in such a way that in one shim the B 1 + was maximized in a circular region of interest around the right superficial femoral artery, while in the other shim the B 1 + in a circular region of interest around the left superficial femoral artery was maximized.…”
Section: Methodsmentioning
confidence: 99%
“…An RF pulse of nominal 90° for the suppression of the veins was applied every TR with a thickness of 116 mm and positioned at a distance of 10 mm below the imaging slice, travelling with the current slice position. TIAMO imaging [15], [16] used CP + and CP 2+ except for the stations of the upper thigh in volunteers where dedicated TIAMO shims had to be calculated. Hence, every slice was acquired twice.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…We designate this technique time-interleaved acquisition of modes (TIAMO) FS because it is similar to the technique that we generally use for the imaging portion of sequences in abdominal imaging protocols. The principle of TIAMO 22,23 is to excite at least 2 different B 1 transmission modes using static RF shimming in an interleaved acquisition. Overall signal homogeneity can be improved by exploiting the complementary RF patterns of the different transmission modes.…”
mentioning
confidence: 99%