2003
DOI: 10.1016/s0960-0760(03)00071-2
|View full text |Cite
|
Sign up to set email alerts
|

Time-resolved fluoroimmunoassay for equol in plasma and urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
39
0

Year Published

2004
2004
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 50 publications
(40 citation statements)
references
References 62 publications
1
39
0
Order By: Relevance
“…In addition to genistein concentrations, which were measured to assess compliance, equol levels were measured to determine which women were able to metabolize this compound. Genistein and equol concentrations in plasma were measured with TR-FIA kits (Labmaster) as previously described (20). Exposure to a sufficient amount of daidzein is required to assess equol producer status.…”
Section: Methodsmentioning
confidence: 99%
“…In addition to genistein concentrations, which were measured to assess compliance, equol levels were measured to determine which women were able to metabolize this compound. Genistein and equol concentrations in plasma were measured with TR-FIA kits (Labmaster) as previously described (20). Exposure to a sufficient amount of daidzein is required to assess equol producer status.…”
Section: Methodsmentioning
confidence: 99%
“…Urine was analyzed for equol by competitive time-resolved fluoroimmunoassay as previously described (Brouwers et al, 2003). Intra-assay coefficients of variation were between 3.4 and 6.9%, and inter-assay coefficients of variation were between 7.4 and 7.7%, at three different concentration levels.…”
Section: Methodsmentioning
confidence: 99%
“…Intra-assay coefficients of variation were between 3.4 and 6.9%, and inter-assay coefficients of variation were between 7.4 and 7.7%, at three different concentration levels. The values were corrected by a formula to correspond to values obtained by reference gas chromatographic-mass spectrometric methods and mean recoveries were 94.3% (Brouwers et al, 2003).…”
Section: Methodsmentioning
confidence: 99%
“…Plasma isoflavones (genistein, daidzein, equol and Odesmethylangolensin) were analyzed by competitive timeresolved fluoroimmunoassay as described previously (Wang et al, 2000;L'Homme et al, 2002;Brouwers et al, 2003). Intraassay variability was 6.3, 7.1 and 8.1% and interassay variability was 9.5, 9.9 and 15.2% for genistein, daidzein and equol, respectively.…”
Section: Data Collection and Analysismentioning
confidence: 99%
“…Before urinary equol analysis, urine was thawed, pooled proportionally for a 3-day sample, aliquoted and lyophilized for equol quantification. Urinary equol was analyzed by competitive time-resolved fluoroimmunoassay and a gas chromatography-mass spectrometry conversion factor applied to these values as described previously (Brouwers et al, 2003).…”
Section: Data Collection and Analysismentioning
confidence: 99%