2011 IEEE International Conference on Rehabilitation Robotics 2011
DOI: 10.1109/icorr.2011.5975473
|View full text |Cite
|
Sign up to set email alerts
|

Tiny hydraulics for powered orthotics

Abstract: Untethered, powered orthotics require an actuation system with power supply and control, transmission line and actuator. Fluid power has unmatched force-to-weight and power-to-weight compared to electromechanical systems, but it is unclear if those same advantages hold for small systems in the 10 to 100 W range. A systems analysis approach suggests that a fluid power system will be lighter than an electromechanical system with the same output power and efficiency if the fluid power is run at pressures over abo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 13 publications
0
8
0
Order By: Relevance
“…More importantly, our results validate a linear relationship between input pressure and output torque that is independent of joint angle. For preliminary assessment, the accumulator was pressurized using a simple hand pump; however, automated pumps and motors capable of producing required pressures with reasonable weight and power consumption for portable use are available [ 28 ] and can be integrated into the PAS in the future now that feasibility of the approach has been established.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…More importantly, our results validate a linear relationship between input pressure and output torque that is independent of joint angle. For preliminary assessment, the accumulator was pressurized using a simple hand pump; however, automated pumps and motors capable of producing required pressures with reasonable weight and power consumption for portable use are available [ 28 ] and can be integrated into the PAS in the future now that feasibility of the approach has been established.…”
Section: Discussionmentioning
confidence: 99%
“…Keeping the mass proximal allows it to be directly transferred to the ground and is not carried by the user or an external power source [ 25 ]. Suitable wearable miniature hydraulic pumps are currently being developed [ 28 ] and adding this unit to our current exoskeleton prototype will keep the weight ( Table 1 ) at or below clinically available electrically driven exoskeletons [ 29 ].…”
Section: Methodsmentioning
confidence: 99%
“…Current off-the-shelf pressure sources are generally limited to compressors and compressed air cylinders, 25 while recent literature has shown a promising explosive actuation modality for soft robots by combustion. 8 In previous work, we have utilized both pressure sources.…”
Section: Energy: Portable Pneumatic Batterymentioning
confidence: 99%
“…Roland Auberger, Michael Friedrich Russold, Robert Riener, Hans Dietl C force and power with a high power/weight ratio [17], especially if hydraulics is used as a passive damper only. However, the control possibilities are limited.…”
Section: Patient Motion Using a Computerized Leg Brace In Everyday Lomentioning
confidence: 99%