1992
DOI: 10.1016/s0002-9394(14)74792-0
|View full text |Cite
|
Sign up to set email alerts
|

Tissue Breakdown and Exposure Associated with Orbital Hydroxyapatite Implants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
62
0
3

Year Published

1994
1994
2014
2014

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 180 publications
(67 citation statements)
references
References 7 publications
2
62
0
3
Order By: Relevance
“…Causes of implant exposure are infection, edema, hemorrhage, and exposure and are related to wrapping material, pegging, surgical technique used, too-large implant size, and surgeon's experience as reported by Viswanathan et al 4 Tension on wound, spicules on HAP implant surface, 21 pressure of prosthesis on conjunctival surface, 9 inadequate vascularization of implant, 2 tissue restitution, or long-term adductive rotation of the implant 22 are other factors that cause anterior tissue breakdown. Shields et al 2 suggested that conjunctival defects that occurred several months or later, might be due to a poorly fitting prostheses causing pressure necrosis, anterior malplacement of the implant, inadequate closure of the Tenon's fascia over the implant, or lack of implant vascularization.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Causes of implant exposure are infection, edema, hemorrhage, and exposure and are related to wrapping material, pegging, surgical technique used, too-large implant size, and surgeon's experience as reported by Viswanathan et al 4 Tension on wound, spicules on HAP implant surface, 21 pressure of prosthesis on conjunctival surface, 9 inadequate vascularization of implant, 2 tissue restitution, or long-term adductive rotation of the implant 22 are other factors that cause anterior tissue breakdown. Shields et al 2 suggested that conjunctival defects that occurred several months or later, might be due to a poorly fitting prostheses causing pressure necrosis, anterior malplacement of the implant, inadequate closure of the Tenon's fascia over the implant, or lack of implant vascularization.…”
Section: Discussionmentioning
confidence: 99%
“…2,[5][6][7][8] The incidence of porous implant exposure in many studies varies from 0-34% with varying follow-up durations. 2,4,6,[8][9][10][11][12][13][14] Exposure rates have been shown to increase after motility peg insertion in some studies. 2,7,8,12,15 Surgical techniques for exposure repair are primary revision 11 and secondary patch grafting using various materials with and without implant removal and exchange.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations