2000
DOI: 10.1055/s-2000-9218
|View full text |Cite
|
Sign up to set email alerts
|

Tissue Harmonic Imaging Sonographie Wird die Bildqualität bei Routine-Ultraschalluntersuchungen im Abdomen verbessert?

Abstract: Image contrast and delineation of organs to neighboring structures as well as reduction of artifacts in cystic structures and vessels are statistically significantly improved with THI sonography using pulse-inversion technology in comparison to conventional sonography.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
1
0
3

Year Published

2001
2001
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(4 citation statements)
references
References 0 publications
0
1
0
3
Order By: Relevance
“…Currently, the image quality of any new US method is routinely evaluated, in terms of contrast, signal-to-noise ratio and resolution, by objectively measuring suitable parameters on images produced by US phantoms [36,37]. Nevertheless, we favoured a subjective approach that is closer to the clinical application of the tested scanners Most previous examinations for the evaluation of technical innovations, such as tissue harmonic imaging [38][39][40][41][42] or photopic imaging, [43,44] but also comparative examinations of similar devices [45,46], evaluate them on the basis of subjective impression; in these, multiple "experienced" examiners usually carry out evaluations in parallel. This study also captured the subjective impressions of experienced examiners.…”
Section: Discussionmentioning
confidence: 99%
“…Currently, the image quality of any new US method is routinely evaluated, in terms of contrast, signal-to-noise ratio and resolution, by objectively measuring suitable parameters on images produced by US phantoms [36,37]. Nevertheless, we favoured a subjective approach that is closer to the clinical application of the tested scanners Most previous examinations for the evaluation of technical innovations, such as tissue harmonic imaging [38][39][40][41][42] or photopic imaging, [43,44] but also comparative examinations of similar devices [45,46], evaluate them on the basis of subjective impression; in these, multiple "experienced" examiners usually carry out evaluations in parallel. This study also captured the subjective impressions of experienced examiners.…”
Section: Discussionmentioning
confidence: 99%
“…B. der Leber, genutzt [14]. Bei der Beurteilung von Gefäßstrukturen ergeben sich Vorteile gegenüber dem konventionellen B-Bild [11].…”
Section: Diskussionunclassified
“…Somit bietet es sich an, den im THI veränderten Bildkontrast sowohl im Rahmen des Tumorscreenings als auch für eine Punktion unter steilen Winkelpositionen auszunutzen. Beispielsweise kann bei Ultraschalluntersuchungen des Abdomens durch THI eine Verbesserung des Bildkontrastes, der Abgrenzbarkeit von Organen gegenüber benachbarten Strukturen und eine Reduktion von Artefakten bei zystischen Strukturen und Gefäßen erreicht werden [14]. Da das THI nun auch für die Beurteilung suspekter Herde in dichtem Weichteilgewebe verfügbar ist, deuten unsere Ergebnisse der Bewertung des Bildkontrastes und der Abgrenzbarkeit verschiedener unabhängiger Untersucher auch diesbezüglich einen Vorteil des THI gegenüber dem konventionellen B-Bild an.…”
Section: Diskussionunclassified
“…Das Tissue Harmonic Imaging (THI) ist eine moderne Ultraschalltechnik, welche zu besserer Abgrenzbarkeit von Organgrenzen beitragen [5] und besonders bei schwierigen Ultraschallbedingungen Vorteile haben soll [6]. Da die harmonischen Schwingungen erst im Gewebe entstehen, werden Artefakte, welche durch Streuung auf dem Weg ins Gewebe entstehen, unterdrückt [7].…”
Section: Abstract: Ultrasound ± Thyroid ± Tissue Harmonic Imagingunclassified