2019
DOI: 10.1007/s11468-019-00961-6
|View full text |Cite
|
Sign up to set email alerts
|

Titanium-Coated Dual-Core D-Shaped SPR-Based PCF for Hemoglobin Sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
30
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 53 publications
(30 citation statements)
references
References 20 publications
0
30
0
Order By: Relevance
“…To alleviate phase-matching problems of optical fiber-based SPR sensors, microstructured optical fiber (MOF)-based SPR sensors have been widely studied owing to their design flexibility [ 9 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 ]. By changing the size, shape, and arrangement of air holes along the propagation direction, the n eff can be tuned to the anticipated values and thus can solve the phase-matching problem between the core mode and the SPP mode [ 9 , 15 , 16 , 17 , 24 , 25 ].…”
Section: Introductionmentioning
confidence: 99%
“…To alleviate phase-matching problems of optical fiber-based SPR sensors, microstructured optical fiber (MOF)-based SPR sensors have been widely studied owing to their design flexibility [ 9 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 ]. By changing the size, shape, and arrangement of air holes along the propagation direction, the n eff can be tuned to the anticipated values and thus can solve the phase-matching problem between the core mode and the SPP mode [ 9 , 15 , 16 , 17 , 24 , 25 ].…”
Section: Introductionmentioning
confidence: 99%
“…Using a linear fitting, see the dashed line in Figure 5 b, we obtained a sensitivity value of nm/RIU. In addition to large values, our system exhibited higher performance than other recent proposals [ 51 , 52 , 53 ], as it can be noted from the figure of merit, , shown in Figure 5 c. The partial results for the performance, resonant wavelengths, , and and R values are summarized in Table 1 , in comparison with their average values at the last row. Because several experimental approaches to develop these types of SPR-PCFs are available, though the experimental realization may be challenging, we expect that the ideas presented here will stimulate exploitation of multiple SPRs for sensing and multiband polarization filtering applications.…”
Section: Resultsmentioning
confidence: 59%
“…MoSe 2 is regarded as the target combination in this case and the constant deposition will increase with a higher proportion of MoSe 2 , the given RI solution makes the fixed value of (dn/dc) ν . Then n d increases correspondingly according to (4), which leads to a larger shift of resonance wavelength and improvement of RI sensitivity. However, the deposition increases the thickness of the layer and also reduces the overlap between the analyte layer and the evanescent field.…”
Section: B Sensitivity Of Mose 2 -Au Based Spr Sensormentioning
confidence: 99%
“…The sensitivity increases first and then decreases. This can also be explained using (4), where the BSA is the analyte with a fixed concentration. In other words, as BSA accumulates and the thickness of MoSe 2 increases, the ionization intensity of the evanescent field is not strong enough to break down the dielectric medium and to excite the SPR phenomenon.…”
Section: Bioaffinity Evaluation Of Mose 2 -Au Based Spr Biosensormentioning
confidence: 99%
See 1 more Smart Citation