2006
DOI: 10.1134/s0016702906090047
|View full text |Cite
|
Sign up to set email alerts
|

Titanium complexation in hydrothermal systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

3
20
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 33 publications
(23 citation statements)
references
References 3 publications
3
20
0
Order By: Relevance
“…By contrast, the diamond‐anvil cell determinations by Audétat & Keppler (2005) gave consistently lower titanium concentrations and much lower dependence on temperature. A three‐parameter fit to the data at 700–1000°C and 7–20 kbar of Antignano & Manning (2008b) ( n = 8, σ = 0.028, 0.85%) reproduces rutile solubilities determined by fluid extraction at 500°C and 1 kbar (Ryzhenko et al. 2006) and 300°C and 200 bar (Knauss et al.…”
Section: Calibration Of the Modelmentioning
confidence: 69%
See 4 more Smart Citations
“…By contrast, the diamond‐anvil cell determinations by Audétat & Keppler (2005) gave consistently lower titanium concentrations and much lower dependence on temperature. A three‐parameter fit to the data at 700–1000°C and 7–20 kbar of Antignano & Manning (2008b) ( n = 8, σ = 0.028, 0.85%) reproduces rutile solubilities determined by fluid extraction at 500°C and 1 kbar (Ryzhenko et al. 2006) and 300°C and 200 bar (Knauss et al.…”
Section: Calibration Of the Modelmentioning
confidence: 69%
“…(1962), Weill & Fyfe (1964), Crerar & Anderson (1971), at isotherms of 25, 100–900°C; (B) solid diamonds: Becker et al. (1983) at 666–700°C; solid circles: Tropper & Manning (2007a) at 700, 800, 900, 1000 and 1100°C; open circles: Walther (1997) at 400, 500 and 600°C; (C) solid diamonds: Fein & Walther (1989) at 400, 500 and 600°C; solid circles: Caciagli & Manning (2003) at 500, 600 and 700°C; (D) solid circles: Antignano & Manning (2008a) at 700, 800 and 900°C; (E) solid circles: Antignano & Manning (2008b) at 800, 900 and 1000°C; open circles: Tropper & Manning (2005) at 1000 and 1100°C; open diamonds: Audétat & Keppler (2005) at 821–1025°C; open triangle: Ryzhenko et al. (2006) at 500°C; (F) solid circles: Tropper & Manning (2007b) at 600, 700, 800, 900 and 1000°C; open diamonds: Strübel (1965) at 200, 300, 400, 500 and 600°C; (G) solid circles: Walther (1986) at 300, 400, 500 and 600°C.…”
Section: Calibration Of the Modelmentioning
confidence: 99%
See 3 more Smart Citations