Titanium dioxide–mediated resistive nanobiosensor for E. coli O157:H7

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 19 publications
(11 citation statements)
references
References 39 publications
0
11
0
Order By: Relevance
“…respectively. The experimentally established LOD for both targets was 10 -19 M which is significantly lower when compared to similar electrochemical sensors for the detection of nucleic acids developed recently [27,[31][32][33][34][35]. The reproducibility of the sensor was calculated for 100 aM (10 -16 M) and 10 fM (10 -14 M) concentrations using the stx1 probe and the relative standard deviation (RSD%) was 12% and 8%, respectively (n=6).…”
Section: Multiplex Sensor Developmentmentioning
confidence: 85%
See 1 more Smart Citation
“…respectively. The experimentally established LOD for both targets was 10 -19 M which is significantly lower when compared to similar electrochemical sensors for the detection of nucleic acids developed recently [27,[31][32][33][34][35]. The reproducibility of the sensor was calculated for 100 aM (10 -16 M) and 10 fM (10 -14 M) concentrations using the stx1 probe and the relative standard deviation (RSD%) was 12% and 8%, respectively (n=6).…”
Section: Multiplex Sensor Developmentmentioning
confidence: 85%
“…However, the complex samples tested by Kashish et al [25] were with the use of PCR amplicons, which means an additional amplification step had to be introduced. In another study, STEC on contaminated chicken samples was directly detected using a sensor developed by Nadzirah et al [27] using interdigitated electrodes (IDEs); which have gained much attention recently [28,29]. Aluminium IDEs modified with TiO2 and APTES were used to immobilise probe DNA and the hybridisation event was detected by conductance.…”
Section: Introductionmentioning
confidence: 99%
“…Titanium dioxide is a material of high technological interest due to its photocatalytic, dielectric, and transparent-conductor features that differ between the crystal phases. 63 The ALD of TiO 2 has been studied widely 64 on different surfaces and using various precursors. TiO 2 is one of the few materials for which the ALD has already been studied by operando APXPS.…”
Section: Research Example: Tio 2 Deposited On Native Oxide-covered Simentioning
confidence: 99%
“…Dimensions in the range of several micrometers have been shown to be effective for biosensor applications. [93,94] However, nanometer-scale of digits is still being studied to achieve workability under ambient condition. An electric field between the fingers is produced when a direct current (DC) or alternating current (AC) is applied on the pads.…”
Section: Interdigitated Electrode (Ide)mentioning