2001
DOI: 10.1002/0471142913.fag0201s00
|View full text |Cite
|
Sign up to set email alerts
|

Titratable Activity of Acid Tastants

Abstract: When measuring acidity in foods and beverages there are two common units of measurement: titratable acidity and pH. There is no direct relationship between pH and titratable acidity, therefore, both must be measured experimentally. Titratable acidity (TA), also referred to as total acidity, measures the total acid content in a food or beverage system and is determined by titration of the acids in the food system with a standard base. BASIC PROTOCOL POTENTIOMETRIC AND COLORIMETRIC ACIDITY TITRATIONS The choice … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…The pH and titratable acidity (TA) of the fruit purees were measured according to the method outlined by Fredrich (2005). After defrosting the frozen sample in a microwave (as recommended by Oszmianski et al, 2009 to reduce drip loss and the possibility of chemical deterioration) the fruit was macerated in a Black & Decker BMC 100 blender (Black & Decker, Mooroolbark, Vic, Australia) at 100 rpm for 2 min.…”
Section: Determination Of Ph and Titratable Aciditymentioning
confidence: 99%
See 1 more Smart Citation
“…The pH and titratable acidity (TA) of the fruit purees were measured according to the method outlined by Fredrich (2005). After defrosting the frozen sample in a microwave (as recommended by Oszmianski et al, 2009 to reduce drip loss and the possibility of chemical deterioration) the fruit was macerated in a Black & Decker BMC 100 blender (Black & Decker, Mooroolbark, Vic, Australia) at 100 rpm for 2 min.…”
Section: Determination Of Ph and Titratable Aciditymentioning
confidence: 99%
“…-milliequivalent weight of the standard; and v -sample volume (ml). Citric acid was selected as the standard acid for these calculations after consulting Table G2.1.1 in Fredrich (2005).…”
Section: Determination Of Ph and Titratable Aciditymentioning
confidence: 99%
“…41). The pH of the extract was obtained using a pH metre (Thermo Scientific Orion Star Series, USA) based from the method of Friedrich (2000). The extractable yield content was determined by placing a 2 ml sample extract in an aluminium disk having a pre-determined constant weight and dried in an oven at 105°C until a constant weight was obtained (Waje et al, 2008).…”
Section: Analysis Of Chemical Propertiesmentioning
confidence: 99%
“…Rhamnosus ) was added (CGD‐Yalacta, Caen, France) as a lactic bacterial starter (Majamaa and others ). Samples were heated at 45 °C for 3.0 h (CGD‐Yalacta recommendations), until the pH, measured by pH‐meter (CyberScan pH 1100 with ATC probe, EutechIntruments, Nijkerk, The Netherlands) following the method of pH analysis of food samples (Friedrich ), reached 4.40 ± 0.05, this value being considered as indicating the end of the fermentation process (Pernoud and others ). DG were stored at 4 °C in closed glass beakers before the analyses in order to curb bacterial development and to minimize structure modifications (Pernoud and others ).…”
Section: Methodsmentioning
confidence: 99%