2002
DOI: 10.1117/12.477475
|View full text |Cite
|
Sign up to set email alerts
|

TOD, NVTherm, and TRM3 model calculations: a comparison

Abstract: At the moment there are three potential models and associated measures to replace the FLIR92 model and the MRTD as the standard for sensor performance characterization and TA range predictions. These are: 1) the NVTherm model that calculates the MRTD-ID, 2) the TRM3 model that calculates the MTDP and 3) the TOD model that calculates the TOD. The three models are grossly different in theoretical approach. We ran the models for the same set of hypothetical cameras. As default sensor, we used a 'typical' under-sa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
16
0

Year Published

2006
2006
2023
2023

Publication Types

Select...
5
3

Relationship

4
4

Authors

Journals

citations
Cited by 16 publications
(17 citation statements)
references
References 7 publications
1
16
0
Order By: Relevance
“…TA models [9][10][11][12][13][14][15][16] such as the TOD model, NVThermIP and TRM3 need to be extended and validated for these largely different target sets, sensor properties, image dynamics and processing techniques, but currently the amount of empirical data is limited and often only addresses one of the above-mentioned differences at the same time. For instance, a large effort of the US research laboratory is directed towards extension of the current models for different target sets such as small arms 17,18 , clothing 19 , paramilitary and civilian vehicles 20 , small boats 21 , or even faces 22 in different spectral regions.…”
Section: Introductionmentioning
confidence: 99%
“…TA models [9][10][11][12][13][14][15][16] such as the TOD model, NVThermIP and TRM3 need to be extended and validated for these largely different target sets, sensor properties, image dynamics and processing techniques, but currently the amount of empirical data is limited and often only addresses one of the above-mentioned differences at the same time. For instance, a large effort of the US research laboratory is directed towards extension of the current models for different target sets such as small arms 17,18 , clothing 19 , paramilitary and civilian vehicles 20 , small boats 21 , or even faces 22 in different spectral regions.…”
Section: Introductionmentioning
confidence: 99%
“…to incorporate signal processing effects. A quantitative comparison between TOD and TTP in 2002 40 showed huge differences. With the newer version 36 the TTP predictions are closer to the TOD although the models still weigh the effects of under-sampling differently 41 .…”
Section: Correspondence With Other Approachesmentioning
confidence: 99%
“…TRM3 is the TA range model associated with the MTDP, and the model is available as a mature software package. A comparison with the two other approaches has been made in 2002 40 and the model has not changed since. The laboratory test can easily be performed with a standard MRTD setup but suffers from the same well-known MRTD observer bias problems which have been overcome with the TOD method.…”
Section: Correspondence With Other Approachesmentioning
confidence: 99%
“…They all claim to cope with well-sampled and under-sampled imagers, but they disagree in the relative importance of detector spacing and diffraction blur on the 'effective resolution' or VA with the sensor. In addition, they behave differently in the transition region 12,13 . For example, a quantitative comparison between TOD and TTP (the model underlying the NVTherm thermal imager range prediction model) in 2002 showed huge differences 12 .…”
Section: Introductionmentioning
confidence: 99%
“…In addition, they behave differently in the transition region 12,13 . For example, a quantitative comparison between TOD and TTP (the model underlying the NVTherm thermal imager range prediction model) in 2002 showed huge differences 12 . Predictions with an updated version of the TTP metric (the basis of the NVThermIP model) are much closer to the TOD 13 : when the performance with blur-limited sensors is set equal, NVThermIP is about 25% more optimistic in range performance prediction for under-sampled imagers than the TOD is.…”
Section: Introductionmentioning
confidence: 99%