2008
DOI: 10.1016/j.sab.2008.10.003
|View full text |Cite
|
Sign up to set email alerts
|

Total reflection x-ray fluorescence as a sensitive analysis method for the investigation of sputtering processes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 8 publications
0
4
0
Order By: Relevance
“…Different approaches are used to satisfy the need of the semiconductor industry for low detection limits and larger wafers. Direct analysis with and without chemical surface treatment as well as sputtering methods were developed [88][89][90][91]. Both uncoated and coated wafers can be characterized.…”
Section: Surface and Thin-layer Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…Different approaches are used to satisfy the need of the semiconductor industry for low detection limits and larger wafers. Direct analysis with and without chemical surface treatment as well as sputtering methods were developed [88][89][90][91]. Both uncoated and coated wafers can be characterized.…”
Section: Surface and Thin-layer Analysismentioning
confidence: 99%
“…In some cases the thickness of the removed layer is determined using interferometry or differential weighing [88][89][90]102]. Sputtering is more elaborate as the sputtered material has to be deposited on a sample support in a proper fashion to be analyzed [91,103]. A customized chamber is often necessary to achieve this.…”
Section: Surface and Thin-layer Analysismentioning
confidence: 99%
“…Sekowski et al applied TXRF for the investigation of sputtering processes (201). They studied an Ar ion beam sputtering process for a Ge target with angles of incidence of 75°and 80°and with an ion energy of 20 keV.…”
Section: Applicationsmentioning
confidence: 99%
“…They also have to be fast and multi-element capable to accommodate the large number of samples. Bench-top total reflection X-ray fluorescence spectrometry (TXRF) offers all these features as it is a non-destructive, surface sensitive analysis method with detection limits in the lower 10 11 to 10 9 atoms cm −2 range (Klockenkämper, 1997; Wobrauschek, 1998, 2007; Streli et al , 1999; Shaffner, 2000; Pahlke et al , 2001; Hellin et al , 2006; Schmeling, 2005; Sekowski et al , 2008; West et al , 2010; Schmeling et al , 2011).…”
Section: Introductionmentioning
confidence: 99%