Toward Wide-Area Oscillation Control Through Doubly-Fed Induction Generator Wind Farms

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
62
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 119 publications
(62 citation statements)
references
References 31 publications
0
62
0
Order By: Relevance
“…In the case of developing wide area damping controllers (WADCs), there are different techniques which have been concentrated for developing WADC strategies including investigating WADC performances as additional controller, [3][4][5][6][7][8][9] applying renewable suppliers as damping controllers in the case of inter-area oscillations, [10][11][12][13][14] use of HVDC links in long transmission lines for controlling the inter-area oscillations between two oscillating areas [15][16][17] and investigating FACTS-based WADCs installed at long transmission lines to damp inter-area oscillations. 18,19 However, in fact, there are various reliability challenges including communication links which avoid the use of WADC schemes in real interconnected power systems.…”
Section: Literature Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…In the case of developing wide area damping controllers (WADCs), there are different techniques which have been concentrated for developing WADC strategies including investigating WADC performances as additional controller, [3][4][5][6][7][8][9] applying renewable suppliers as damping controllers in the case of inter-area oscillations, [10][11][12][13][14] use of HVDC links in long transmission lines for controlling the inter-area oscillations between two oscillating areas [15][16][17] and investigating FACTS-based WADCs installed at long transmission lines to damp inter-area oscillations. 18,19 However, in fact, there are various reliability challenges including communication links which avoid the use of WADC schemes in real interconnected power systems.…”
Section: Literature Reviewmentioning
confidence: 99%
“…Based on (14) and (15), at first all of the nominated global signals are evaluated by (14) in order to find the signals with the best observability for specific inter-area modes. Then the most observable signals are processed by (15) within a set of specific inter-area modes from which a set of controlling signals with the best controllability with respect to specified inter-area modes are determined.…”
Section: Identifying Input/output Wide Area Signalsmentioning
confidence: 99%
“…The delay dependent stability is studied for constant and time‐dependent delays in the input signal of the controller. The Particle Swarm Optimization‐based wide area oscillation control is proposed in Ref . The effect of latency in the presence of wind farms is also considered for effective mitigation of the interarea oscillation.…”
Section: Other Pmu Applicationsmentioning
confidence: 99%
“…Also for AAPC in damping control, power system stabilizer (PSS) added to wind generator [8,9] proves efficient to prevent power grid oscillations.…”
Section: Introductionmentioning
confidence: 99%
“…A method for parameter optimization is then developed based on the simulation testing results. Several software such as Simulink [9,16], DigSILENT [7], and package DSA Tools [13] are widely used to test AAPC performance in corresponding cases. One more method is based on hardware simulation or offline recording, such as the apparatus namely Gridsim used by State Grid of China [14].…”
Section: Introductionmentioning
confidence: 99%