2021
DOI: 10.21203/rs.3.rs-136708/v1
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Towards a New Pseudo-quantitative Approach to Evaluate the Ionization Response of Nitrogen Compounds in Complex Matrices

Abstract: Ultra high-resolution mass spectrometry (FT-ICR MS) coupled to electrospray ionization (ESI) provides unprecedented molecular characterization of complex matrices such as petroleum products. However, ESI faces major ionization competition phenomena that prevent the absolute quantification of the compounds of interest. On the other hand, comprehensive two-dimensional gas chromatography (GC × GC) coupled to specific detectors (HRMS or NCD) is able to quantify the main families identified in these complex matrice… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
6
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 24 publications
0
6
0
Order By: Relevance
“…Nitrogen and sulfur families have been attributed according to DBE values. 15,21 Chemometric Approach. Here, the value of 100 stands for the range of the number of carbon atoms (from 1 to 100), 25 for the range of aromaticity values (from 1 to 25), and 108 for the number of acquired spectra on the whole data set (6 replicates for each of the 18 vacuum gas oil samples).…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Nitrogen and sulfur families have been attributed according to DBE values. 15,21 Chemometric Approach. Here, the value of 100 stands for the range of the number of carbon atoms (from 1 to 100), 25 for the range of aromaticity values (from 1 to 25), and 108 for the number of acquired spectra on the whole data set (6 replicates for each of the 18 vacuum gas oil samples).…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…18−20 In a previous study, a data formatting strategy has been introduced in order to simultaneously manage DBE values, number of carbon atoms, and sample for the exploration of a single ionization mode (APPI(+)) focusing only on sulfur compounds. 21 In order to simultaneously explore the data obtained for basic/neutral nitrogen and sulfur compounds from several ionization modes, a low-level data fusion strategy will be applied to generate a new tensor from the three-way arrays obtained for each ionization mode. Multiway approaches will be then required for this tensor exploration such as Parallel Factor Analysis (PARAFAC).…”
mentioning
confidence: 99%
“…Energy & Fuels Component Analysis (PCA) has been applied on each array. 17 (2) A low-level data fusion method has been applied to concatenate the previously obtained 3D cubes along the DBE axis obtaining one hypercube of size 50 × 75 × 138 containing the information on the three ionization modes. In this specific case, the PARAFAC method has been applied using the alternating least squares algorithm (ALS).…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…The results obtained considering APPI(+)-FT-ICR/MS data have been exhaustively discussed in a previous work. 17 Six principal components have been considered as significant and explain 96.7% of the total variance. The score plot obtained over PC1−PC2 is available in Figure S5 in the Supporting Information.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
See 1 more Smart Citation