2007
DOI: 10.1140/epjd/e2007-00189-2
|View full text |Cite
|
Sign up to set email alerts
|

Towards direct mass measurements of nobelium at SHIPTRAP

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
62
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 100 publications
(63 citation statements)
references
References 40 publications
1
62
0
Order By: Relevance
“…02030-p.3 of c from this investigation was found to be 0.99 (9), which is comparable to the value of c = 0.898 (8) obtained from a series of cyclotron frequency measurements of singly-charged 85 Rb ions conducted at ISOLTRAP [33].…”
Section: Inpc 2013supporting
confidence: 82%
See 1 more Smart Citation
“…02030-p.3 of c from this investigation was found to be 0.99 (9), which is comparable to the value of c = 0.898 (8) obtained from a series of cyclotron frequency measurements of singly-charged 85 Rb ions conducted at ISOLTRAP [33].…”
Section: Inpc 2013supporting
confidence: 82%
“…The coupling of Penning traps to rare-isotope-beam facilities has revolutionized the field of mass spectrometry of exotic nuclides. Presently, the operational Penning traps for mass measurements of exotic nuclides are ISOLTRAP [6], CPT [7], JYFLTRAP [8], SHIPTRAP [9], LEBIT [10], TRIGA-SPEC [11], and TITAN [12]. The TITAN Penning trap mass spectrometer is coupled to the rare-isotope-beam facility ISAC [13] Figure 1.…”
Section: Introductionmentioning
confidence: 99%
“…These setups include in chronological order of the start of their data taking ISOLTRAP [11] at ISOLDE/CERN, the Canadian Penning trap (CPT) [12] at the Argonne National Laboratory ANL, the JYFLTRAP facility [13] in Jyväskylä, SHIPTRAP [14] at GSI/Darmstadt, LEBIT [15] at NSCL (MSU, East Lansing), and TITAN [16] at TRIUMF/Vancouver. TRIGA-TRAP [17] is the first Penning trap mass spectrometer at a nuclear research reactor and started taking off-line data at TRIGA-Mainz in 2009 [18].…”
Section: Penning-trap Mass Spectrometrymentioning
confidence: 99%
“…A direct mass measurement is not prone to uncertainties introduced by missing excited states as they are often populated in the α-decay of odd-odd or odd-A nuclei. The Penning-trap mass spectrometer SHIPTRAP [14] at GSI is presently the only one worldwide where masses of nuclides above fermium can be measured. It has been recently demonstrated that Penning trap mass measurements of heavy radionuclides with production rates of only about one ion per minute are presently feasible with SHIPTRAP.…”
Section: Penning Trap Mass Measurements On Heavy and Superheavy Nuclidesmentioning
confidence: 99%
“…This scheme, which is illustrated in Fig. 1(a), has been tested and commissioned at GSI [8,9,10] using SHIPTRAP [11] and TASISpec [12]. The latter was originally developed for superheavy-element spectroscopy behind the gas-filled separator TASCA at GSI Darmstadt [1].…”
Section: Introductionmentioning
confidence: 99%