2014
DOI: 10.1088/0067-0049/211/2/31
|View full text |Cite
|
Sign up to set email alerts
|

Tr-Lif Lifetime Measurements and Hfr+cpol Calculations of Radiative Parameters in Vanadium Atom (V I)

Abstract: Radiative lifetimes of 79 levels belonging to the 3d 3 4s4p, 3d 4 4p, 3d 3 4s5p, 3d 4 5p, and 3d 3 4s4d configurations of V i with energy from 26,604.807 to 46,862.786 cm −1 have been measured using time-resolved laser-induced fluorescence (TR-LIF) spectroscopy in laser-produced plasma. The lifetime values reported in this paper are in the range of 3.3-494 ns, and the uncertainties of these measurements are within ±10%. A good agreement was obtained with previous data. HFR+CPOL calculations have been performed… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 17 publications
1
7
0
Order By: Relevance
“…These are discussed in Section 3. We also compare theoretically calculated log(gf ) values of Kurucz (2007) and recent results of Wang et al (2014), which combine measured lifetimes and theoretical branching fractions, with our new data, and confirm that experimentally measured log(gf) values are more reliable where these exist. Additionally, we provide log (gf ) values for 13 lines that have not been reported in any previous study, nine of which are in the infrared at wavelengths longer than 1.6 μm, which was the longest wavelength for any previously reported log(gf ) value in V I (Whaling et al 1985).…”
Section: Introductionsupporting
confidence: 81%
See 3 more Smart Citations
“…These are discussed in Section 3. We also compare theoretically calculated log(gf ) values of Kurucz (2007) and recent results of Wang et al (2014), which combine measured lifetimes and theoretical branching fractions, with our new data, and confirm that experimentally measured log(gf) values are more reliable where these exist. Additionally, we provide log (gf ) values for 13 lines that have not been reported in any previous study, nine of which are in the infrared at wavelengths longer than 1.6 μm, which was the longest wavelength for any previously reported log(gf ) value in V I (Whaling et al 1985).…”
Section: Introductionsupporting
confidence: 81%
“…Comparison of the new log(gf ) values with theoretical values (Kurucz 2007) and values obtained with theoretical BFs and measured level lifetimes (Wang et al 2014) is shown in Figure 7. The improved accuracy of laboratory-measured log(gf ) values over theoretical values is clear.…”
Section: Resultsmentioning
confidence: 92%
See 2 more Smart Citations
“…These effects can be eliminated by changing the slit width of the monochromator, reducing the energies of ablation and excitation lasers, and increasing the delay time between the ablation and excitation pulses. Moreover, a magnetic field of about 100 G produced by a pair of Helmholtz coils was applied to wash out possible quantum beats caused by the earth magnetic field and to effectively reduce recombination between electrons and ions (Wang et al 2014).…”
Section: Lifetime Measurementsmentioning
confidence: 99%