Trace‐level analysis of polychlorinated biphenyls, organochlorine pesticides and polycyclic aromatic hydrocarbons in human plasma or serum by dispersive liquid–liquid microextraction and gas chromatography–tandem mass spectrometry

Abstract: A method to determine 8 polychlorinated biphenyls (PCBs), 23 organochlorine pesticides (OCPs) and 16 polycyclic aromatic hydrocarbons (PAHs) was described using dispersive liquid-liquid microextraction (DLLME) of a small amount of plasma or serum sample and gas chromatography-tandem mass spectrometry (GC-MS/MS).The appropriate selection of the extraction solvent and dispersing solvent contributes to a high extraction yield and a clean extract. To verify the developed method, the interference, linearity of the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…The carrier gas was helium (purity 99.99 %) with a flow rate of 1 Ml/min. RT: 15.27–22.29 min” [ 404 ] Plasma/serum 23 0.001–0.029 0.002–0.093 85.9–109 1.97–19.6 GC-MS/MS: “The oven temperature program was started at 70 °C, increased to 240 °C at 20 °C/min, and continuously increased to 310 °C at 8 °C/min and maintained at the final temperature for 11 min” [ 405 ] Plasma/serum 7) 0.02–0.07 4–40 GC-MS/MS: “The GC oven program was set to following values: 115 °C (2 min), 4 °C/min, 260 °C (1 min), 30 °C/min, 320 °C (2 min)” [ 406 ] serum 26 7 × 10 −5 -0.01344 30–124 HRMS/HRMS [ 407 ] Blood serum 11 74–120 <20 GC-MS/MS, UHPLC–MS/MS [ 101 ] Human tissue (liver, kidney, heart, spleen, lung, brain and abdominal fat) 20 1.0–16 85–109 <12 GTC-MS: “Splitless, the GC oven program started with an isothermal stage at 100 °C for 0.5 min, increasing at 10 °C/min ∼180 °C, and then at 2 °C/min ∼225 °C (2 min), to finally reach 265 °C at a rate of 20 °C/min, which was maintained for 1 min” [ 44 ] Human blood 8 0.004; 5 × 10 −5 ng a for detector Ave: 95 GC-ECD [ 408 ] ...…”
Section: Results and Discussion: Literature Reviewmentioning
confidence: 99%
“…The carrier gas was helium (purity 99.99 %) with a flow rate of 1 Ml/min. RT: 15.27–22.29 min” [ 404 ] Plasma/serum 23 0.001–0.029 0.002–0.093 85.9–109 1.97–19.6 GC-MS/MS: “The oven temperature program was started at 70 °C, increased to 240 °C at 20 °C/min, and continuously increased to 310 °C at 8 °C/min and maintained at the final temperature for 11 min” [ 405 ] Plasma/serum 7) 0.02–0.07 4–40 GC-MS/MS: “The GC oven program was set to following values: 115 °C (2 min), 4 °C/min, 260 °C (1 min), 30 °C/min, 320 °C (2 min)” [ 406 ] serum 26 7 × 10 −5 -0.01344 30–124 HRMS/HRMS [ 407 ] Blood serum 11 74–120 <20 GC-MS/MS, UHPLC–MS/MS [ 101 ] Human tissue (liver, kidney, heart, spleen, lung, brain and abdominal fat) 20 1.0–16 85–109 <12 GTC-MS: “Splitless, the GC oven program started with an isothermal stage at 100 °C for 0.5 min, increasing at 10 °C/min ∼180 °C, and then at 2 °C/min ∼225 °C (2 min), to finally reach 265 °C at a rate of 20 °C/min, which was maintained for 1 min” [ 44 ] Human blood 8 0.004; 5 × 10 −5 ng a for detector Ave: 95 GC-ECD [ 408 ] ...…”
Section: Results and Discussion: Literature Reviewmentioning
confidence: 99%
“…In DLPME, the extractant and dispersant are injected into the sample solution at the same time, then the extractant is dispersed into tiny droplets for extraction, and finally it sinks to the bottom or floats on the liquid surface to achieve phase separation. Due to its simple operation, rapidity, and high enrichment factor (EF), it has been widely used in the extraction and enrichment of trace compounds in various complex matrices such as TCMs, food, environmental water, plasma, urine, and other samples [19][20][21][22][23].…”
Section: Introductionmentioning
confidence: 99%