2009
DOI: 10.1016/j.measurement.2009.07.015
|View full text |Cite
|
Sign up to set email alerts
|

Traceability enhancement in angle measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 4 publications
0
6
0
Order By: Relevance
“…During this operation, movements of the centre are measured by two pick-ups of small linear displacement. Errors in radial direction are evaluated according to the value of displacement of the centre of the roundness measure in two perpendiculars to each other and to the axis of rotation directions or by assessing of the Lissajouis figures developed by vectorial sum of the displacements mentioned above [5]. During the calibration of precision spindles a glass or of other material made spherical (usually, semispherical) or cylindrical body (artefact) is used.…”
Section: Subjectivity Of Assessment Of Radial Rotation Errorsmentioning
confidence: 99%
“…During this operation, movements of the centre are measured by two pick-ups of small linear displacement. Errors in radial direction are evaluated according to the value of displacement of the centre of the roundness measure in two perpendiculars to each other and to the axis of rotation directions or by assessing of the Lissajouis figures developed by vectorial sum of the displacements mentioned above [5]. During the calibration of precision spindles a glass or of other material made spherical (usually, semispherical) or cylindrical body (artefact) is used.…”
Section: Subjectivity Of Assessment Of Radial Rotation Errorsmentioning
confidence: 99%
“…The research performed shows good possibilities to create the flat angle standard of π rad and to reproduce it at any high level metrological laboratory [6,7]. The main setup for this angle standard establishment is shown in Fig.…”
Section: Development Of the π π π π Rad Angle Standardmentioning
confidence: 99%
“…These are uncorrelated inputs. According to [7,8], the combined variance will be: of the standard angle of π rad determination equal to 0.06″…0.08″ (sec of arc; k=2). There are assumptions to reach a better result of the standard angle determination by improving sensitivity and repeatability of the reading instruments.…”
Section: Uncertainty Of Measurementmentioning
confidence: 99%
“…Mechatronic elements and devices are used to determine measuring errors and therefore to control the positioning of measured elements. Such measured objects used in angle calibration are precision rotary encoders, circular scales and multi -angular prism (polygon) [1,2]. For the last few years various attempts have been undertaken to automate the process of angle calibration.…”
Section: Introductionmentioning
confidence: 99%