Traceability of vibration and shock measurements by laser interferometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
18
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(18 citation statements)
references
References 4 publications
0
18
0
Order By: Relevance
“…The ZFM will be effective not only for developing a low‐cost calibration instrument based on the LMM using a low‐cost model digitizer but also for developing a high‐precision instrument using a high‐end model digitizer. The ZFM will be effective with a combination of most of the algorithm for detecting each zero crossing, 1–3,13 such as polynomial approximation or sine curve fit, as well as linear interpolation used in the experiment described in this article.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The ZFM will be effective not only for developing a low‐cost calibration instrument based on the LMM using a low‐cost model digitizer but also for developing a high‐precision instrument using a high‐end model digitizer. The ZFM will be effective with a combination of most of the algorithm for detecting each zero crossing, 1–3,13 such as polynomial approximation or sine curve fit, as well as linear interpolation used in the experiment described in this article.…”
Section: Discussionmentioning
confidence: 99%
“…Requirements for estimating the frequency of a single sinusoid with high resolution and high sampling rate have increased in various industrial and research applications. In the field of high‐precision mechanical measurement, such as the dynamic calibration of accelerometers 1–3 and the dynamic calibration of force transducers, 4–6 it is sometimes required to measure the Doppler frequency shift appearing at the interferometer's output port. For measuring the Doppler frequency shift, an electronic frequency counter or a digitizer, that is, a high‐speed analog‐to‐digital converter, is usually used.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…In vibration and shock calibration laser interferometer is used to measure movement and obtain traceability to SI unit [4] . Grating usually used in length and angle measurement.…”
Section: Using Circular Grating Measuring Angular Movementmentioning
confidence: 99%
“…Increasing the measurement accuracy of acceleration Using laser interferometer instead of acceleration transducer to measure acceleration has several advantages. First, it is an absolute measuring method, which is used in national acceleration standards with the best accuracy [3] . Second, it is a noncontact measuring method which eliminates the mass of acceleration transducer from the total mass and the system acceleration distribution is simplified.…”
Section: Introductionmentioning
confidence: 99%