1988
DOI: 10.1016/s0015-0282(16)60202-9
|View full text |Cite
|
Sign up to set email alerts
|

Transabdominal versus transvaginal ultrasound scanning of ovarian follicles: are they comparable?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
3
0
1

Year Published

1993
1993
2011
2011

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 2 publications
1
3
0
1
Order By: Relevance
“…Estimated interobserver and intraobserver variability for each of the five separate studies was less than 10%, which was consistent with previous studies (55). The accuracy and consistency among users of high-resolution ultrasonography for the identification and measurement of ovarian follicles has been previously documented in women (55,56) and using animal models (57).…”
Section: Ultrasonographic Assessmentssupporting
confidence: 86%
“…Estimated interobserver and intraobserver variability for each of the five separate studies was less than 10%, which was consistent with previous studies (55). The accuracy and consistency among users of high-resolution ultrasonography for the identification and measurement of ovarian follicles has been previously documented in women (55,56) and using animal models (57).…”
Section: Ultrasonographic Assessmentssupporting
confidence: 86%
“…After the introduction of TV scanning method many investigators concentrated on the accuracy of assessment of follicular dynamics [7][8][9]. A good number of studies were done later comparing transabdominal (TA) and transvaginal (TV) methods of studying the pelvic organs [10][11][12][13]. TVS is still to achieve momentum in India mainly due to (i) non availability of TV probes, (ii) ignorance/reluctance of the referring physicians (iii) lack of adequate knowledge of TVS and altered anatomical orientation.…”
Section: Discussionmentioning
confidence: 99%
“…Evidences also suggest that transabdominal methods underestimates the number of follicles than does TVS. TV ultrasound measurement of follicular size has lower intra and inter observer variability [12]. Yee et al [14] and Musoles et al [15] have demonstrated that TV scanning methods showed a higher correlation between follicular diameter and follicular fluid volume as compared to the TAS method.…”
Section: Discussionmentioning
confidence: 99%
“…Grâce [7] ; les mesures en échographie endovaginale sont similaires à celles obtenues par l'échographie sus-pubienne [35] ; la mesure du diamètre la plus fiable est celle de la moyenne des deux plus grands diamètres orthogonaux [31] ; le diamètre moyen du follicule a une bonne corrélation avec le volume folliculaire dans les formes rondes. Mais cette corrélation n'est plus exacte lorsque la forme du follicule est ellipsoïde ou irrégulière [33] ; la reproductibilité de la mesure du diamètre en cycle monofolliculaire est assez médiocre.…”
Section: En Cycle Multifolliculaire L'image éChographique D'ununclassified