2015
DOI: 10.1097/hco.0000000000000219
|View full text |Cite
|
Sign up to set email alerts
|

Transcatheter aortic valve replacement in bicuspid aortic valve disease

Abstract: The existing literature supports the use of TAVR in selected high-risk BiAV patients, although the final role of this technique in this cohort of patients can only be established once a larger, preferably randomized, study comparing TAVR with surgery is performed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
12
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 17 publications
(13 citation statements)
references
References 30 publications
1
12
0
Order By: Relevance
“…Namely, it should not be based solely on the annular but rather on supra-annular measurements taking into account the intracommissural distance. The observed device undersizing in our registry suggests that operators applied this new strategy [29]. It should also be taken into account that the new-generation valves are equipped with sealing cuff that could further overcome the previously observed drawbacks of undersizing.…”
Section: Discussionmentioning
confidence: 79%
“…Namely, it should not be based solely on the annular but rather on supra-annular measurements taking into account the intracommissural distance. The observed device undersizing in our registry suggests that operators applied this new strategy [29]. It should also be taken into account that the new-generation valves are equipped with sealing cuff that could further overcome the previously observed drawbacks of undersizing.…”
Section: Discussionmentioning
confidence: 79%
“…The best method for valve sizing in BAV has yet to be defined. The usual perimeter/area at the annulus is still the mainstay way for sizing, but there have been reports and presentations taking structures above the annulus into account for sizing purposes . The practice usually recommended a smaller valve size than annular measurements.…”
Section: Methodsmentioning
confidence: 99%
“…27 For instance, several institutions have published observational studies that proclaim the feasibility and safety of performing TAVR for bicuspid AS. [28][29][30] However, there have been no large-scale, randomized control trials designed specifically for this congenital patient As the indications for TAVR have expanded over time (Figure 2…”
Section: Expanding Indicationsmentioning
confidence: 99%