Transcranial Access Using Fluoroscopic Flat Panel Detector CT Navigation

Abstract: SUMMARY:FPCT and navigation software on contemporary fluoroscopic units perform imaging of a quality comparable with conventional CT. They can accurately guide percutaneous procedures, providing live instrument visualization and the capability to re-image without patient transfer. FPCT navigation was used in the placement of a ventricular drain in a 62-year-old woman for subarachnoidrelated hydrocephalus by using an otherwise standard bedside technique. Ventriculostomy catheter placement was technically succes… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
8
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 18 publications
1
8
0
Order By: Relevance
“…This is similar to the reported accuracy of 1.1 mm in phantom studies in frameless neurosurgical intraoperative guidance systems 27. Our clinical needle tip targeting accuracy appears to be better than the recent reports of 3.0–3.5 mm error in standard and intracranial phantom studies using the same integrated 3D fluoroscopic guidance system 28 29. This discrepancy may be due to more precise needle placement with respect to the 3D overlay target by the neurointerventionalists in our study, but may also be due to the verification method used in our study—namely, a follow-up cone-beam CT.…”
Section: Discussionsupporting
confidence: 86%
“…This is similar to the reported accuracy of 1.1 mm in phantom studies in frameless neurosurgical intraoperative guidance systems 27. Our clinical needle tip targeting accuracy appears to be better than the recent reports of 3.0–3.5 mm error in standard and intracranial phantom studies using the same integrated 3D fluoroscopic guidance system 28 29. This discrepancy may be due to more precise needle placement with respect to the 3D overlay target by the neurointerventionalists in our study, but may also be due to the verification method used in our study—namely, a follow-up cone-beam CT.…”
Section: Discussionsupporting
confidence: 86%
“…A notable difference between the techniques that we used in this study and most stereotactic systems used for neurosurgical intracranial access are that we passed the needle freehand without any additional stabilisation of the needle. Nonetheless, the fidelity of the navigation system is sufficient for targeting larger anatomic targets such as the ventricles, or pathology such as a haematoma, and could potentially be applied to navigation towards MRI-defined targets with similar accuracy 1 3 11. This system could be applied to intracranial access in either a hybrid operating room or an interventional angiographic suite with appropriate safety precautions.…”
Section: Discussionmentioning
confidence: 99%
“…The concept of FDCT procedural guidance has been successfully applied with slight variations to percutaneous procedures in the brain, head and neck, and spine 1–3 7 8 10 11 14–16. There are some notable advantages to using FDCT guidance as opposed to conventional CT, including potentially lower radiation doses depending on individual procedure specifics and the fact that a traditional CT room stays functional for diagnostic studies 4 28 29.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations