Transcutaneous and intra-arterial blood gas monitoring???a comparison during apnoea testing for the determination of brain death

Abstract: Intra-arterial (i.a.) and transcutaneous (t.c.) blood gas monitoring were compared with in vitro blood gas analysis (abg) during apnoea testing for the determination of brain death in a prospective observational study. All three methods were used simultaneously in 19 patients in whom brain death was suspected. Brain death was confirmed in each case adhering to the recommendations of the Scientific Advisory Board of the German Federal Chamber of Physicians which demand a PCO2 of at least 60 mmHg. In vitro param… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2003
2003
2011
2011

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 19 publications
0
6
0
Order By: Relevance
“…Although the ‘gold standard’ method is arterial blood gas sampling, this technique is invasive, and alternative endtidal pCO 2 monitoring via a mask is quite uncomfortable. Transcutaneous measurements have been found to be accurate in paediatric conditions [14]and to be able to detect pCO 2 changes during diagnosis of brain death [15]; thus, there is no reason to assume a systematic difference in recordings from young and old subjects. Therefore, we are confident that pCO 2 changes were not a factor for the different autoregulatory response in patients and controls in our study.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although the ‘gold standard’ method is arterial blood gas sampling, this technique is invasive, and alternative endtidal pCO 2 monitoring via a mask is quite uncomfortable. Transcutaneous measurements have been found to be accurate in paediatric conditions [14]and to be able to detect pCO 2 changes during diagnosis of brain death [15]; thus, there is no reason to assume a systematic difference in recordings from young and old subjects. Therefore, we are confident that pCO 2 changes were not a factor for the different autoregulatory response in patients and controls in our study.…”
Section: Discussionmentioning
confidence: 99%
“…pCO 2 was measured transcutaneously over the skin of the right forearm ulnar flexor muscle using a chemical method (Radiometer, Copenhagen, Denmark). This method has been found to be as accurate as endtidal CO 2 monitoring or arterial blood gas analysis [13, 14, 15]. …”
Section: Methodsmentioning
confidence: 99%
“…It is unclear whether this device reduces blood gas testing (and thus cost) during the apnea test. 28,29 Conclusion. Apneic oxygenation diffusion to determine apnea is safe, but there is insufficient evidence to determine the comparative safety of techniques used for apnea testing.…”
Section: Analysis Of Evidencementioning
confidence: 98%
“…In order to avoid repeated arterial blood gas testing, continuous intra-arterial and transcutaneous blood gas measuring were compared with in vitro arterial blood gas analysis during apnea testing. There were several technical difficulties and no clear advantages, so that neither procedure could replace the standard method of arterial blood gas testing [57].…”
Section: Apnea Testingmentioning
confidence: 99%