Transcutaneous monitoring of diaphragm activity as a measure of work of breathing in preterm infants

Abstract: Objective: Monitoring work of breathing (WOB) is important to assess the pulmonary condition and adjust respiratory support in preterm infants. Conventional WOB measurement (esophageal pressure, tidal volume) is invasive and we hypothesized that monitoring diaphragm activity could be a noninvasive alternative to estimate WOB. The objective was to determine the correlation between conventional WOB measures and diaphragm activity, in preterm infants.Methods: WOB and diaphragm activity, measured with transcutaneo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 28 publications
0
7
0
Order By: Relevance
“…Such a measurement is difficult to calibrate properly and is affected by signal filtration and, impedance, and by sleep stage 35 . A proper estimation of breathing effort would have required esophageal pressure measurement, 5,36 and diaphragm and esophageal pressure measurement are expected to show only a modest correlation 37 . Despite these limitations, we find diaphragm EMG useful, providing reasonable repeatability 2,16 …”
Section: Discussionmentioning
confidence: 92%
See 1 more Smart Citation
“…Such a measurement is difficult to calibrate properly and is affected by signal filtration and, impedance, and by sleep stage 35 . A proper estimation of breathing effort would have required esophageal pressure measurement, 5,36 and diaphragm and esophageal pressure measurement are expected to show only a modest correlation 37 . Despite these limitations, we find diaphragm EMG useful, providing reasonable repeatability 2,16 …”
Section: Discussionmentioning
confidence: 92%
“…and diaphragm and esophageal pressure measurement are expected to show only a modest correlation. 37 Despite these limitations, we find diaphragm EMG useful, providing reasonable repeatability. 2,16…”
Section: Study Limitationsmentioning
confidence: 90%
“…In contrast to the study of Helfenbein et al we placed the electrodes at the height of the diaphragm in accordance with previous dEMG studies as we were solely interested in diaphragm activity, which may have improved dEMG‐signal quality as crosstalk at this position is reduced 4,14,15 . On the other hand, the used ECG/CI electrodes were not actively shielded, like in previous dEMG studies in neonates 4,6,16,17 . In these studies, the dedicated dEMG cables were micro coaxial cables using active shielding to prevent capacitive coupling of the measurement wire with the environment 18 .…”
Section: Discussionmentioning
confidence: 99%
“… 4 , 14 , 15 On the other hand, the used ECG/CI electrodes were not actively shielded, like in previous dEMG studies in neonates. 4 , 6 , 16 , 17 In these studies, the dedicated dEMG cables were micro coaxial cables using active shielding to prevent capacitive coupling of the measurement wire with the environment. 18 This reduced power supply interference and cable movement artifacts.…”
Section: Discussionmentioning
confidence: 99%
“…Diaphragm electrical activity (Edi) can be measured easily by electromyography using a modified gastric feeding tube or transcutaneous surface electrodes, providing an objective measure of respiratory effort [10][11][12][13]. The maximal Edi during inspiration (Edimax) reflects inspiratory effort and is responsible for the size of a breath, whilst the minimal Edi at end-expiration (Edimin) reflects tonic activity required to maintain functional residual capacity (FRC) and prevent atelectasis [10,14].…”
Section: Introductionmentioning
confidence: 99%