2017
DOI: 10.1016/j.jim.2016.11.003
|View full text |Cite
|
Sign up to set email alerts
|

Transferring Luminex® cytokine assays to a wall-less plate technology: Validation and comparison study with plasma and cell culture supernatants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
23
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
10

Relationship

7
3

Authors

Journals

citations
Cited by 27 publications
(23 citation statements)
references
References 20 publications
0
23
0
Order By: Relevance
“…To measure IFN-␥ and IL-4 in the supernatants, a sandwich enzyme-linked immunosorbent assay (ELISA) method was employed, using mouse IFN-␥ and IL-4 ELISA kits (eBioscience) per the manufacturer's instructions. To measure secreted levels of IL-2, IL-10, IL-12, and TNF-␣, a Luminex-based assay was used, as previously described, that utilizes a Luminex kit from Bio-Rad and a wall-less 96-well plate from Curiox (68). Cytokine concentrations in the supernatant were calculated based on a standard curve, and for each sample duplicate wells were averaged.…”
Section: Methodsmentioning
confidence: 99%
“…To measure IFN-␥ and IL-4 in the supernatants, a sandwich enzyme-linked immunosorbent assay (ELISA) method was employed, using mouse IFN-␥ and IL-4 ELISA kits (eBioscience) per the manufacturer's instructions. To measure secreted levels of IL-2, IL-10, IL-12, and TNF-␣, a Luminex-based assay was used, as previously described, that utilizes a Luminex kit from Bio-Rad and a wall-less 96-well plate from Curiox (68). Cytokine concentrations in the supernatant were calculated based on a standard curve, and for each sample duplicate wells were averaged.…”
Section: Methodsmentioning
confidence: 99%
“…BAL fluid and lung tissue supernatants were thawed, and cytokine levels were quantitated by using a Bio-Rad (Hercules, CA) Pro mouse cytokine T H 1/T H 2 (IFN-␥, IL-4, IL-5, IL-10, IL-13, IL-17, and TNF-␣) kit with 96-well DropArray DA-bead plates and a DropArray LT210 washing station MX instrument from Curiox (San Carlos, CA), as previously described (59). The results were acquired on a Luminex Magpix instrument using Bio-Plex MP and Bio-Plex Manager software.…”
Section: Methodsmentioning
confidence: 99%
“…The supernatant samples were tested for levels of IL-2, IL-4, IL-5, IL-10, IL-12(p70), GM-CSF, IFN-γ and TNF-α using a Bio-Plex Pro Mouse Th1/Th2 8-plex kit (Bio-Rad, Hercules). To save material and costs, and to increase the sensitivity of the experiment, the kit was used in combination with DA-Bead plates (Curiox Biosystems, Singapore) as previously described [37]. Samples were run on a Bio-Plex Magpix multiplex reader according to manufacturer's recommendations (Luminex, Austin).…”
Section: Methodsmentioning
confidence: 99%