2017
DOI: 10.1016/j.enbuild.2017.07.083
|View full text |Cite
|
Sign up to set email alerts
|

Transformation of a university building into a zero energy building in Mediterranean climate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
24
0
5

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 58 publications
(32 citation statements)
references
References 18 publications
3
24
0
5
Order By: Relevance
“…in the energy performance of the building by numerical or experimental methods. In these studies, it was concluded that the pros and cons of implementing this typology of walls in buildings with different climate conditions [17][18][19]. Aldawoud et al [20] investigated the effects of different design scenarios on the airflow and energy performance of an office building with a double skin facade in Dubai city.…”
Section: Introductionmentioning
confidence: 99%
“…in the energy performance of the building by numerical or experimental methods. In these studies, it was concluded that the pros and cons of implementing this typology of walls in buildings with different climate conditions [17][18][19]. Aldawoud et al [20] investigated the effects of different design scenarios on the airflow and energy performance of an office building with a double skin facade in Dubai city.…”
Section: Introductionmentioning
confidence: 99%
“…e.g. Fluent [44,115,126,187] (within ANSYS at present), ANSYS CFX [78,81], Solidworks Flow Simulation [188], and CFD Flex [189]. Table 8 provides some references for CFD model used in current Trombe wall studies.…”
Section: Cfd Modelmentioning
confidence: 99%
“…Table 8 provides some references for CFD model used in current Trombe wall studies. [33,58,142,158,189,[196][197][198][199][200][201][202][203]. It is also the calculation base for the other evaluation indexes of Trombe…”
Section: Cfd Modelmentioning
confidence: 99%
“…In [4] and [5] different costefficient retrofit scenarios are discussed for typical educational buildings built around 1960-1970, taking into account occupants' wellbeing. In [6] and [7] two Mediterranean case studies are converted into zero energy buildings while considering IEQ aspects. Ascione et al [8] implement the refurbishment of an ancient university building in Italy by means of model simulation and with the investigation of potential savings.…”
Section: Introductionmentioning
confidence: 99%