2009
DOI: 10.1049/iet-pel:20070422
|View full text |Cite
|
Sign up to set email alerts
|

Transformerless three-phase on-line UPS with high performance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0
2

Year Published

2012
2012
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 38 publications
(16 citation statements)
references
References 7 publications
0
11
0
2
Order By: Relevance
“…The parallel operation of multiple Voltage Source Converters (VSC) was widely investigated by researchers, with the aim to realize Uninterruptible Power Supply (UPS) [8] or self-sustaining micro-grids. In case of micro-grid, the grid stability must be guaranteed by the control strategy of the connected VSCs, that have to cooperate for a smart managing of the distributed energies sources; a feature that is not envisaged by existing grid-connected converters.…”
Section: State Of Art Of Micro-grid Conceptsmentioning
confidence: 99%
“…The parallel operation of multiple Voltage Source Converters (VSC) was widely investigated by researchers, with the aim to realize Uninterruptible Power Supply (UPS) [8] or self-sustaining micro-grids. In case of micro-grid, the grid stability must be guaranteed by the control strategy of the connected VSCs, that have to cooperate for a smart managing of the distributed energies sources; a feature that is not envisaged by existing grid-connected converters.…”
Section: State Of Art Of Micro-grid Conceptsmentioning
confidence: 99%
“…Three-phase UPSs found commercially and in scientific work are based, with slight variations, on a classical topology employing two-level PWM converters [4][5][6][7]. Despite being able to maintain power quality on both the mains side and the load side, its efficiency is limited due to the large switching losses in the electronic switches.…”
Section: Introductionmentioning
confidence: 99%
“…Generally, the CM component suppression strategies are based on the converter architecture [10]- [12], modulation strategy [13], [14], and CM filter [15], [16] [19], the wye connection point of the AC side filter capacitors [13], and connection of the DC-link capacitor midpoint and wye point of AC filter capacitors [20], [21], were proposed to be used as neutral line for three-leg converter. The neutral line can also be supplied by an additional leg [13], [22].…”
Section: Introductionmentioning
confidence: 99%
“…A passive CM filter can be composed of a CM inductor [23], [24], AC side bypass LRC filter [7], [20], [25] and DC-side bypass filter [26]. For the CM inductor filter, when the converter is voltage control, the voltage quality is determined by the CM current, and consequently, in three-leg converter four-wire system, the filter is non influential when the AC grid is no loads or with light loads, as it will be explained in the following.…”
Section: Introductionmentioning
confidence: 99%