2016
DOI: 10.1016/j.fusengdes.2016.01.062
|View full text |Cite
|
Sign up to set email alerts
|

Transient analyses on the cooling channels of the DEMO HCPB blanket concept under accidental conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
7
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 8 publications
0
7
0
Order By: Relevance
“…The main objective of this analysis was to determine if FWMU can provide relevant information on the behavior of a DEMO blanket first wall under a LOFA event as modeled in [14]. Having U-shaped channels (in contrast to one-way cooling channels for DEMO FW) it is important to select the right inlet and outlet configuration that results in a temperature distribution similar to the that of a DEMO blanket under steady state conditions.…”
Section: Preliminary Fluid Dynamics and Thermal Simulation Of The Tes...mentioning
confidence: 99%
See 4 more Smart Citations
“…The main objective of this analysis was to determine if FWMU can provide relevant information on the behavior of a DEMO blanket first wall under a LOFA event as modeled in [14]. Having U-shaped channels (in contrast to one-way cooling channels for DEMO FW) it is important to select the right inlet and outlet configuration that results in a temperature distribution similar to the that of a DEMO blanket under steady state conditions.…”
Section: Preliminary Fluid Dynamics and Thermal Simulation Of The Tes...mentioning
confidence: 99%
“…Having U-shaped channels (in contrast to one-way cooling channels for DEMO FW) it is important to select the right inlet and outlet configuration that results in a temperature distribution similar to the that of a DEMO blanket under steady state conditions. Additionally, in terms of dynamic behavior, it is important to check if the mock-up can produce similar transients when the flow rate changes as the one obtained in [14]. In order to clarify these two points, using Ansys CFX, a two-channel model was created to simulate the transient behavior of the temperature field in a blanket FW during a LOFA event: one channel operating at its nominal parameters while the other is subject to a partial (50% flow rate drop from the nominal value) or total LOFA event, similarly to the cases investigated in [14].…”
Section: Preliminary Fluid Dynamics and Thermal Simulation Of The Tes...mentioning
confidence: 99%
See 3 more Smart Citations