2017
DOI: 10.15199/48.2017.02.33
|View full text |Cite
|
Sign up to set email alerts
|

Transient Analysis of a Railgun with Iron Core

Abstract: A calculation and measurement results of transients for an iron-core electrodynamic launcher have been presented in the paper. The magnetostatic field calculations have been made with using the Maxwell-ANSYS software, while the circuit part of the mathematical model has been implemented in MATLAB/Simulink package. The measurement verification has been carried out with using the original laboratory stand. The transients of excitation current, capacitor voltage and projectile velocity have been compared. A good … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 11 publications
0
2
0
Order By: Relevance
“…There are only small visible differences arising from the different velocities of the projectile. It should be mentioned that a very high repeatability of shots for both constructions was obtained (Waindok and Piekielny, 2017). On this basis, a comparative analysis of the effectiveness of investigated railguns could be carried out.…”
Section: Calculation and Measurement Resultsmentioning
confidence: 93%
“…There are only small visible differences arising from the different velocities of the projectile. It should be mentioned that a very high repeatability of shots for both constructions was obtained (Waindok and Piekielny, 2017). On this basis, a comparative analysis of the effectiveness of investigated railguns could be carried out.…”
Section: Calculation and Measurement Resultsmentioning
confidence: 93%
“…The ferromagnetic cores (Figs. 2(a) and 2(b)) were used in order to focus the magnetic field lines in the projectile area [16]. In the case of the ICPM construction, permanent magnets as an additional source of a magnetic field (NdFeB) were implemented [17], (Figs.…”
Section: Physical Modelsmentioning
confidence: 99%