2022
DOI: 10.1016/j.engstruct.2021.113604
|View full text |Cite
|
Sign up to set email alerts
|

Translational stiffness and resistance of sandwich panel connections at elevated temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…However, for Sample 2 at 20 min, the maximum displacement in the order of 14 mm in the opposite direction of the furnace (outside) was reached. These results can be compared with those obtained by Garifulin et al where they describe that the tests were stopped when the samples reached a displacement of 20 mm, both at room temperature and at high temperatures, taking into account that they used a displacement-controlled test machine, with a loading speed set at 1 mm/min [6].…”
Section: Load Bearing Capacitymentioning
confidence: 91%
See 3 more Smart Citations
“…However, for Sample 2 at 20 min, the maximum displacement in the order of 14 mm in the opposite direction of the furnace (outside) was reached. These results can be compared with those obtained by Garifulin et al where they describe that the tests were stopped when the samples reached a displacement of 20 mm, both at room temperature and at high temperatures, taking into account that they used a displacement-controlled test machine, with a loading speed set at 1 mm/min [6].…”
Section: Load Bearing Capacitymentioning
confidence: 91%
“…On the other hand, a thermographic camera and laser tape were also used to monitor and measure the horizontal deformation of the systems during the tests. Further all results were visually inspected throughout the procedures, same methodology applied in the research of Garifulin et al [6].…”
Section: Methodsmentioning
confidence: 99%