Photons Plus Ultrasound: Imaging and Sensing 2021 2021
DOI: 10.1117/12.2579056
|View full text |Cite
|
Sign up to set email alerts
|

Transparent ultrasound transducers for multiscale photoacoustic imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 0 publications
1
9
0
Order By: Relevance
“…MRR sensors usually have a wider bandwidth than other types of US sensors [43,44,54,55]. The piezoelectricbased sensors maintain high sensitivity over a wide bandwidth [26,28,31,61]. The CMUT sensors generally have high sensitivity over a narrower bandwidth [33,34].…”
Section: Discussion and Perspectivesmentioning
confidence: 99%
See 2 more Smart Citations
“…MRR sensors usually have a wider bandwidth than other types of US sensors [43,44,54,55]. The piezoelectricbased sensors maintain high sensitivity over a wide bandwidth [26,28,31,61]. The CMUT sensors generally have high sensitivity over a narrower bandwidth [33,34].…”
Section: Discussion and Perspectivesmentioning
confidence: 99%
“…Therefore, transparent PMN-PT ceramics and single crystals will become the materials with better application prospects for transparent US transducers due to their higher temperature stability and higher piezoelectric performance. In 2021, Chen et al reported a PMN-PT single crystal-based transparent US senor with a 14 MHz center frequency [61].…”
Section: Transparent Piezoelectric-based Us Sensorsmentioning
confidence: 99%
See 1 more Smart Citation
“…These crystals exhibit near perfect transparency, an ultrahigh piezoelectric coefficient, an excellent electromechanical coupling factor, and a large electro-optical coefficient. Dangi et al [138] applied this transparent PMN-PT based US transducer in PA imaging. This high sensitivity transparent US transducer could provide more flexibility of probe design, further facilitating the translation of this endoscopic PA imaging technology to clinical use.…”
Section: Discussionmentioning
confidence: 99%
“…For example, the above mentioned glass as the first backing may be replaced by a transparent epoxy block coated with low temperature ITO deposition as a conductive connection for the ground to reduce the significant mass-loading effect from the glass slide. Further a two matching layer approach [52] or novel matching layers that use translucent particles (glass beads) also have the potential to help improve the transmit and receive bandwidths of the TUT arrays. For reducing the grating lobes, a geometry of fully diced through piezoelectric material would help reduce the cross-talk, which will likely reduce the grating lobes presented.…”
Section: Quad-mode Imaging Validationmentioning
confidence: 99%