2008
DOI: 10.2116/analsci.24.1329
|View full text |Cite
|
Sign up to set email alerts
|

Transport Properties of Binary Mixtures of Carbon Dioxide and 1-Butyl-3-methylimidazolium Hexafluorophosphate Studied by Transient Grating Spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
25
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(29 citation statements)
references
References 45 publications
4
25
0
Order By: Relevance
“…A similar enhancement in transport phenomena, induced by CO 2 dissolution, was sometimes reported by several researchers [14][15][16][17][18][19][20]. Kimura et al [20] [17] and typical 1-alkyl-3-methylimidazolium salts with ½PF 6 À , ½BF 4 À , and ½Tf 2 N À anions [42], though Zhang et al [16] reported the anomalous pressure dependence of conductivity in [BMIM][PF 6 ]; the conductivity remained unchanged at lower pressures and increased at higher pressures, which might be possibly caused by water contamination. These facts could support the linear pressure dependence of diffusion coefficients of molecular as well as ionic species in IL-CO 2 systems, in spite of the non-linear pressure dependence observed in the present study.…”
Section: Resultssupporting
confidence: 82%
See 1 more Smart Citation
“…A similar enhancement in transport phenomena, induced by CO 2 dissolution, was sometimes reported by several researchers [14][15][16][17][18][19][20]. Kimura et al [20] [17] and typical 1-alkyl-3-methylimidazolium salts with ½PF 6 À , ½BF 4 À , and ½Tf 2 N À anions [42], though Zhang et al [16] reported the anomalous pressure dependence of conductivity in [BMIM][PF 6 ]; the conductivity remained unchanged at lower pressures and increased at higher pressures, which might be possibly caused by water contamination. These facts could support the linear pressure dependence of diffusion coefficients of molecular as well as ionic species in IL-CO 2 systems, in spite of the non-linear pressure dependence observed in the present study.…”
Section: Resultssupporting
confidence: 82%
“…The viscosities [14,15] and electrical conductivities [16,17] 6 ] saturated with CO 2 were investigated at high pressures. Spectroscopic techniques have also been employed to estimate the liquid properties in view of solute molecules dissolved in ILs [18][19][20].…”
Section: Introductionmentioning
confidence: 99%
“…33 Generally, the major sources of errors are caused by the diffraction of acoustic waves, acoustic streaming, local sample heating by acoustic waves (particularly near the transducer), and the lack of parallelism between the transducer and reflector. 7 The last, but most sophisticated method for measurements in ILs, is the transient grating spectroscopy, 12,[19][20][21][22][23][24] which is classified as an optic method. The principle of this method is described in detail by Eichler et al 44 and is based on the formation of gratings in an electric laser field in weakly absorbing samples.…”
Section: Speed Of Sound Measurementsmentioning
confidence: 99%
“…The search queries were "ionic liquid" together with "speed of sound", "sound velocity", "ultrasonic sound velocity", "ultrasonic velocity", "sound speeds", "ultrasonic speed", "speed of (Table S1). 1,2,[12][13][14][15][18][19][20][21][22][23][25][26][27][28][29][30][31]33,35,36,45, 12,14,18,19,22,23,25,30,34 The purity of these ILs is compared in Table 4. Among those ILs, two were the most investigated in the literature:…”
Section: Overview Of Existing Data For Ionic Liquidsmentioning
confidence: 99%
“…Generally, the TG method seems more suitable for measuring ultrasound velocity than the ultrasound absorption, and in the case of RTILs, a few suchlike reports can be found. [15][16][17][18][19] The abovementioned study of the ultrasound absorption and the recently observed nonNewtonian behavior along with lack of the dynamic crossover in the range of 1.2-1. as well as deeper knowledge about molecular dynamics may be additionally interesting to the research community. To complete the ultrasound absorption study and to obtain a set of 6 absorption measurements were carried out using a measuring set based on the standard pulse method with a variable path length.…”
Section: Introductionmentioning
confidence: 99%