Treatment of cardiogenic shock with the hemopump left ventricular assist device

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0
5

Year Published

1994
1994
2013
2013

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 78 publications
(19 citation statements)
references
References 13 publications
0
14
0
5
Order By: Relevance
“…device is the same as the 21 Fr. device [7,8]: the inflow cannula is positioned across the aortic valve with the inlet residing in the left ventricle and the pump outlet positioned above the aortic valve. During operation of the pump, the ventricle is actively decompressed and blood flow is delivered to the aorta (Fig.…”
Section: Fr Hemopumpo Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…device is the same as the 21 Fr. device [7,8]: the inflow cannula is positioned across the aortic valve with the inlet residing in the left ventricle and the pump outlet positioned above the aortic valve. During operation of the pump, the ventricle is actively decompressed and blood flow is delivered to the aorta (Fig.…”
Section: Fr Hemopumpo Systemmentioning
confidence: 99%
“…Clinical trials were conducted in the United States to evaluate the system in the treatment of potentially reversible cardiogenic shock. These trials demonstrated significant improvement in the hemodynamic condition of patients with shock and improvement in survival of selected patients [8]. However, the large diameter of the pump prevented successful placement in 23% of patients and thus posed a significant barrier to its clinical use.…”
Section: Introductionmentioning
confidence: 97%
“…Thus, in combination with modern revascularization techniques, the 21-Fr HP system with its sta bilizing effects on hemodynamics as well as myocardial protective features could promote advances in treatment of cardiogenic shock. Recent clinical trials demonstrated improve ment in the hemodynamic condition of pa tients with shock [13] and improvement in survival of selected patients [14].…”
Section: Hp Left-ventricular Assist In Cardiogenic Shockmentioning
confidence: 99%
“…In clinical trials performed in the United States, the large diameter of the HP prevented successful placement in 23% of patients and thus posed a significant barrier to its clinical use [14], Recently, a newly designed miniatu rized HP system has been developed for per cutaneous access. The system is 14 Fr in outer diameter and is based on a mixed flow rotary pump and capable of flow rates of up to 2.2 liters/min ( fig.…”
Section: New Developmentsmentioning
confidence: 99%
“…Micro-axial blood pumps have been revealed as an useful tool either for short term or for chronic left ventricular assistance [1][2][3][4][5][6][7]. The Hemopump (Medtronic, Minneapolis, USA) is a device based on the principle of the screw pump: it furnishes, by conversion from electric energy, rotating energy to a high speed rotor [8].…”
Section: Introductionmentioning
confidence: 99%