1971
DOI: 10.1016/s0021-9673(00)97825-7
|View full text |Cite
|
Sign up to set email alerts
|

Treatment of controlled pore glass with poly(ethylene oxide) to prevent adsorption of rabies virus

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
7
0

Year Published

1979
1979
2011
2011

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 78 publications
(9 citation statements)
references
References 5 publications
2
7
0
Order By: Relevance
“…However, viruses have been shown to elute in wide bands from these columns (Hiatt et al 1971), supporting our findings that CPG does not have the resolution necessary to separate complex assemblages of aquatic viruses.…”
Section: Column Chromatographysupporting
confidence: 86%
See 1 more Smart Citation
“…However, viruses have been shown to elute in wide bands from these columns (Hiatt et al 1971), supporting our findings that CPG does not have the resolution necessary to separate complex assemblages of aquatic viruses.…”
Section: Column Chromatographysupporting
confidence: 86%
“…In previous studies, controlled-pore glass has been used to separate viruses from debris in lysates by eluting the viruses in the exclusion volume (Gschwender et al 1969), and two viruses differing widely in size and shape have previously been separated in this way (Haller 1965). However, viruses have been shown to elute in wide bands from these columns (Hiatt et al 1971), supporting our findings that CPG does not have the resolution necessary to separate complex assemblages of aquatic viruses.…”
Section: V) Size-exclusion Chromatography With Sephacrylsupporting
confidence: 79%
“…Using the surface force technique, Luckam [22,23] observed that steric repulsion with PEO is mainly due to osmotic repulsion between interdigitated PEO chains. Jeon et al [24,25] Interfacial properties of PEO-treated biomaterials PEO-rich surfaces have been prepared by physical adsorption of PEO [26,27]. Only high molecular weight PEO (Mw > 100000) can be effectively adsorbed on hydrophobic surfaces [28].…”
Section: Steric Repulsion With Terminally Attached Peomentioning
confidence: 99%
“…PEO surfaces have but for other areas as well, such as membranes for been prepared by physical adsorption of PEO onto exseparation processes, biosensors, chromatographic isting substrates. [18][19][20][21] Only high-molecular-weight PEO supports, contact lenses, immunoassay, blood, and (mol. wt.…”
Section: Introductionmentioning
confidence: 99%