2020
DOI: 10.3390/jcm9092922
|View full text |Cite
|
Sign up to set email alerts
|

Treatment of Mandible Fractures Using a Miniplate System: A Retrospective Analysis

Abstract: Three-dimensional (3D) mini plate systems are used in the treatment of mandibular fractures. The system is advantageous in comparison to conventional plates due to the stabilization of tension and compression areas, improved initial stability, and biomechanical behavior. The aim of this retrospective study was to evaluate the use of a 3D miniplate system for the treatment of patients with mandibular fractures. Patients with mandibular fractures treated with a 3D plate system at the Department of Oral and Maxil… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(17 citation statements)
references
References 25 publications
1
9
0
Order By: Relevance
“…The geometry of the 3-D plate permits three dimensional stability and opposes torque forces while ensuring a low profile and malleability [22]. A three-dimensional plate is a modification of Champy's system in which two plates are connected by vertical bars, neutralizing tension and compression forces at the same time [23]. The present study compared the effectiveness of the 3-D miniplate system, in comparison to the 2-D miniplate system, for the treatment of isolated mandibular angle fractures in terms of achieving balanced dental occlusion.…”
Section: Discussionmentioning
confidence: 99%
“…The geometry of the 3-D plate permits three dimensional stability and opposes torque forces while ensuring a low profile and malleability [22]. A three-dimensional plate is a modification of Champy's system in which two plates are connected by vertical bars, neutralizing tension and compression forces at the same time [23]. The present study compared the effectiveness of the 3-D miniplate system, in comparison to the 2-D miniplate system, for the treatment of isolated mandibular angle fractures in terms of achieving balanced dental occlusion.…”
Section: Discussionmentioning
confidence: 99%
“…The presented articles [5][6][7][8][9][10][11] describe the treatment of fractures of the mandible by various modern methods. In all these cases, the technique of bony defect filling with a collagen osteotropic material was used, but the timing of full regeneration of bone tissue was not indicated.…”
Section: Discussionmentioning
confidence: 99%
“…The experience of many studies shows that patients with mandibular fractures demand an individual approach in the choice of the treatment method, because there may be in a combination with bony lesions of different nature, odontogenic infection, fractures in different areas of the mandible or facile skeleton, etc. [5][6][7][8][9][10]13]. In all these cases, a collagen osteotropic material was used to fill the bony defect.…”
Section: Discussionmentioning
confidence: 99%
“…Grafts of different nature are widely used in traumatology, oncology, surgery, also in oral and maxillofacial surgery [5][6]. There are accurate requirements for graft properties as biological compatibility, absence of unpleasant reactions (allergy, reaction 'transplant against host'), availability and others [5].…”
Section: Introductionmentioning
confidence: 99%