2018
DOI: 10.1016/j.ophtha.2018.02.003
|View full text |Cite
|
Sign up to set email alerts
|

Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
115
1
8

Year Published

2018
2018
2022
2022

Publication Types

Select...
4
4
1

Relationship

2
7

Authors

Journals

citations
Cited by 226 publications
(128 citation statements)
references
References 40 publications
0
115
1
8
Order By: Relevance
“…The total rate of needling within one year after surgery was 16% in both groups. Similarly, Gedde et al described a needling rate of 14% for their trabeculectomy cohort [18]. In contrast, Mansouri et al reported a considerably higher needling rate of 45% in the…”
Section: Discussionmentioning
confidence: 95%
“…The total rate of needling within one year after surgery was 16% in both groups. Similarly, Gedde et al described a needling rate of 14% for their trabeculectomy cohort [18]. In contrast, Mansouri et al reported a considerably higher needling rate of 45% in the…”
Section: Discussionmentioning
confidence: 95%
“…The most recent example of newness outweighing data-driven change is the micropulse method of diode ciliodestruction, for which no studies have been published that compare it to standard diode application. In contrast, in an impressively designed and implemented study, trabeculectomy has been shown to have advantages over tube shunt surgery in a controlled, randomized clinical trial for eyes without past glaucoma surgery [36]. To be sure, improvements in glaucoma surgery are truly needed and the excitement in the many attempts shows this need.…”
Section: The Emperor's New Surgeriesmentioning
confidence: 99%
“…5 In contrast, human pericardium (Tutoplast) has a thin configuration and is not associated with postoperative inflammation, which makes it a favorable choice to cover the tube in GDD implantation. 3 The rationale for using patch graft is to protect the tube from direct eyelid repetitive trauma and broaden the elevated area to reduce the risk of tube erosion. In spite of covering the seton with patch graft, tube erosion occurs.…”
Section: Discussionmentioning
confidence: 99%
“…3 While bleb-related complications of trabeculectomy are not seen after glaucoma drainage device (GDD) implantations, 4 these devices predispose patients to certain adverse events related to the implantation of a foreign body on the surface of the eye. One unique complication is the exposure of the glaucoma drainage device.…”
Section: Introductionmentioning
confidence: 99%