Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Background There is much heterogeneity in the instrumentation used for parenchymal transection in minimally invasive liver surgery. Instruments specifically designed for robotic parenchymal transection of the liver are lacking. We aim to gain insight into the safety and effectiveness of the SynchroSeal (Intuitive Surgical, Inc., Sunnyvale, CA), a novel bipolar electrosurgical device, in the context of liver surgery. Methods The present study is a post-hoc analysis of prospectively collected data from patients undergoing robotic liver resection (RLR) using the SynchroSeal in two high-volume centres. The results of the SynchroSeal were compared with that of the previous generation bipolar-sealer; Vessel Sealer Extend (Intuitive Surgical, Inc., Sunnyvale, CA) using propensity score matching, after excluding the first 25 Vessel Sealer procedures per center. Results During the study period (February 2020–March 2023), 155 RLRs meeting the eligibility criteria were performed with the SynchroSeal (after implementation in June 2021) and 145 RLRs with the Vessel Sealer. Excellent outcomes were achieved when performing parenchymal transection with the SynchroSeal; low conversion rate (n = 1, 0.6%), small amounts of intraoperative blood loss (median 40 mL [IQR 10–100]), short hospital stays (median 3 days [IQR 2–4]), and adequate overall morbidity (19.4%) as well as severe morbidity (11.0%). In a matched comparison (n = 94 vs n = 94), the SynchroSeal was associated with less intraoperative blood loss (48 mL [IQR 10–143] vs 95 mL [IQR 30–200], p = 0.032) compared to the Vessel Sealer. Other perioperative outcomes were similar between the devices. Conclusion The SynchroSeal is a safe and effective device for robotic liver parenchymal transection.
Background There is much heterogeneity in the instrumentation used for parenchymal transection in minimally invasive liver surgery. Instruments specifically designed for robotic parenchymal transection of the liver are lacking. We aim to gain insight into the safety and effectiveness of the SynchroSeal (Intuitive Surgical, Inc., Sunnyvale, CA), a novel bipolar electrosurgical device, in the context of liver surgery. Methods The present study is a post-hoc analysis of prospectively collected data from patients undergoing robotic liver resection (RLR) using the SynchroSeal in two high-volume centres. The results of the SynchroSeal were compared with that of the previous generation bipolar-sealer; Vessel Sealer Extend (Intuitive Surgical, Inc., Sunnyvale, CA) using propensity score matching, after excluding the first 25 Vessel Sealer procedures per center. Results During the study period (February 2020–March 2023), 155 RLRs meeting the eligibility criteria were performed with the SynchroSeal (after implementation in June 2021) and 145 RLRs with the Vessel Sealer. Excellent outcomes were achieved when performing parenchymal transection with the SynchroSeal; low conversion rate (n = 1, 0.6%), small amounts of intraoperative blood loss (median 40 mL [IQR 10–100]), short hospital stays (median 3 days [IQR 2–4]), and adequate overall morbidity (19.4%) as well as severe morbidity (11.0%). In a matched comparison (n = 94 vs n = 94), the SynchroSeal was associated with less intraoperative blood loss (48 mL [IQR 10–143] vs 95 mL [IQR 30–200], p = 0.032) compared to the Vessel Sealer. Other perioperative outcomes were similar between the devices. Conclusion The SynchroSeal is a safe and effective device for robotic liver parenchymal transection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.