Trends in service time of pacemakers in the Netherlands: a long-term nationwide follow-up study

Abstract: AimsAfter decades of experience and strongly improved technology, service time of pacemaker generators is expected to increase. To test this hypothesis, we conducted a retrospective review of a large cohort of patients with a pacemaker.MethodsWe reviewed data collected between 1984 and 2006 in the first national Dutch pacemaker registry. This registry covered 96% of all generators implanted. We analysed the time of and reason for explantation of pacemaker generators. A 7-year follow-up interval after first imp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
9
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 22 publications
1
9
0
Order By: Relevance
“…The duration of time from the initial implantation to replacing a PPM generator varied between 6 and 7 years in different studies [ 17 , 18 ]. In our study, survival duration was from less than 1 year to longer than 10 years.…”
Section: Discussionmentioning
confidence: 99%
“…The duration of time from the initial implantation to replacing a PPM generator varied between 6 and 7 years in different studies [ 17 , 18 ]. In our study, survival duration was from less than 1 year to longer than 10 years.…”
Section: Discussionmentioning
confidence: 99%
“…We are aware that up to 60% of deaths have not been registered in SPRN . Therefore, it is expected that a large proportion of patients may have died during follow‐up.…”
Section: Discussionmentioning
confidence: 99%
“…For this purpose, first implantations during the years 1984–2000 could be used, while data from 2001 to 2007 were used for follow‐up only. We chose a 7‐year follow‐up period because the mean duration of follow‐up for explanted pacemaker generators falls within this time interval …”
Section: Methodsmentioning
confidence: 99%
“…Implants that last longer, thereby reducing the risks associated with explantation and replacement, could reduce the profits of manufacturers and profit-driven healthcare providers. This may be the reason why pacemakers are not built to last as long as would be technologically possible [15,17]. The major manufacturers put new pacemaker models on the market about every 6 or 12 months, often with new, not very urgent functionalities that draw upon the battery [18,19].…”
Section: The Responsibility Of Manufacturersmentioning
confidence: 99%