2022
DOI: 10.1016/j.matpr.2022.02.055
|View full text |Cite
|
Sign up to set email alerts
|

Tresca stress evaluation of Metal-on-UHMWPE total hip arthroplasty during peak loading from normal walking activity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
26
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9
1

Relationship

4
6

Authors

Journals

citations
Cited by 25 publications
(26 citation statements)
references
References 10 publications
0
26
0
Order By: Relevance
“…The contour is accessed using the post viewer from ABAQUS/CAE 16.4-1 on S, S22 menu [ 31 ]. To explain changes in the contact pressure contour, five phases were selected as representatives of the 32 phases under gait cycle, referring to previous research conducted by Ammarullah et al [ 26 ]. It can be seen that the distribution of contact pressure will widen as the value of contact pressure and the applied force increase.…”
Section: Resultsmentioning
confidence: 99%
“…The contour is accessed using the post viewer from ABAQUS/CAE 16.4-1 on S, S22 menu [ 31 ]. To explain changes in the contact pressure contour, five phases were selected as representatives of the 32 phases under gait cycle, referring to previous research conducted by Ammarullah et al [ 26 ]. It can be seen that the distribution of contact pressure will widen as the value of contact pressure and the applied force increase.…”
Section: Resultsmentioning
confidence: 99%
“…The analysis of literature data shows that research on this issue is conducted in various directions. An example is using computational models to the analyze Tresca stresses in metal bearings, as well as to assess delamination-fretting damage [ 34 , 36 ]. According to Ammarullah et al, it is the Ti6Al4V-on-Ti6Al4V bearings that show the superior Tresca stress reduction properties among other metal-on-metal bearings [ 36 ].…”
Section: Introductionmentioning
confidence: 99%
“…UHMWPE is known for its high wear resistance, high toughness, high impact strength and low friction coefficient, as well as durability, biocompatibility and chemical inertness. These properties make UHMWPE the material of choice for a wide range of applications, such as chain guides, star wheels, truck beds, lead acid battery separators, as well as knee, shoulder and hip implants in modern medicine [ 2 , 3 ]. Owing to its high impact strength and toughness, UHMWPE is also used as armor protection [ 4 , 5 ].…”
Section: Introductionmentioning
confidence: 99%