Triboionization in Discontinuous Atmospheric Pressure Inlet for a Miniature Ion Trap Mass Spectrometer

Abstract: Discontinuous atmospheric pressure interface (DAPI) consisting of a pinch valve, a silicone tube, and two metal capillaries has been widely used in miniature mass spectrometry. It is interesting that clear ion signals could be observed even when the extra ionization source was turned off. In-depth analysis suggested that this new ionization phenomenon known as triboionization is based on the surface friction on the inner surface of the silicone tube during the on/off of the pinch valve. In this study, triboion… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(8 citation statements)
references
References 55 publications
0
8
0
Order By: Relevance
“…Another fascinating application involves the ionization of gas molecules via dielectric breakdown for chemical analysis using a mass spectrometer. 104 Static charge was first generated on the inner surface of a silicone tube (inner diameter of 1 mm) by contact electrification of the inner surface (i.e., via pressing the "pinch valve"; Figure 6d). A vapor containing the analyte (i.e., anisole) was passed through the tube and analyzed using a mass spectrometer.…”
Section: Applications Of Charge Dissipation Via Dielectric Breakdownmentioning
confidence: 99%
See 3 more Smart Citations
“…Another fascinating application involves the ionization of gas molecules via dielectric breakdown for chemical analysis using a mass spectrometer. 104 Static charge was first generated on the inner surface of a silicone tube (inner diameter of 1 mm) by contact electrification of the inner surface (i.e., via pressing the "pinch valve"; Figure 6d). A vapor containing the analyte (i.e., anisole) was passed through the tube and analyzed using a mass spectrometer.…”
Section: Applications Of Charge Dissipation Via Dielectric Breakdownmentioning
confidence: 99%
“…(d and e) Reproduced with permission (copyright 2021, American Chemical Society). 104 (f) Scheme illustrates the operation of a DC-TENG (direct-current triboelectric nanogenerator), and (g) current obtained by the DC-TENG in air and oxygen (O 2 ) under atmospheric pressure. (f and g) Reproduced with permission (copyright 2021, Elsevier).…”
Section: Charge Dissipation By Disrupting Co-localization Of Charge A...mentioning
confidence: 99%
See 2 more Smart Citations
“…The particles were directly sucked into the ion trap when the pinch valve of the DAPI opened. [26][27][28][29][30][31] CAPI is the other vacuum system used for a miniaturized mass spectrometer, 32,33 but only for small molecule instead of particles currently. The CAPI let air samples introduced continuously.…”
Section: Introductionmentioning
confidence: 99%