2019
DOI: 10.1016/j.jmbbm.2018.10.031
|View full text |Cite
|
Sign up to set email alerts
|

Tribological behavior of Ti-6Al-4V against cortical bone in different biolubricants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 62 publications
(25 citation statements)
references
References 40 publications
0
25
0
Order By: Relevance
“…Due to the rather high stiffness of such plate constructs, the undesired stress-shielding effect in load-bearing implants cannot be excluded and may impact union or induce even non-unions ( Viljanen et al, 1995 ). Once the healing process is completed and implants are no longer functional ( Rosa et al, 2016 ), their presence might interfere with facial growth (in adolescents), increase the infection risk, or be a source of metallic ion release ( Katou et al, 1996 ; Armencea et al, 2019 ; Wang et al, 2019 ). Furthermore, when positioned in close proximity to the mental nerve, chronic pain and paraesthesia can result ( Hachleitner et al, 2014 ).…”
Section: Introductionmentioning
confidence: 99%
“…Due to the rather high stiffness of such plate constructs, the undesired stress-shielding effect in load-bearing implants cannot be excluded and may impact union or induce even non-unions ( Viljanen et al, 1995 ). Once the healing process is completed and implants are no longer functional ( Rosa et al, 2016 ), their presence might interfere with facial growth (in adolescents), increase the infection risk, or be a source of metallic ion release ( Katou et al, 1996 ; Armencea et al, 2019 ; Wang et al, 2019 ). Furthermore, when positioned in close proximity to the mental nerve, chronic pain and paraesthesia can result ( Hachleitner et al, 2014 ).…”
Section: Introductionmentioning
confidence: 99%
“…Hank's solution is the most widely used simulated human body fluid, in corrosion tests as an aggressive medium and in wear tests as a bio-lubricant. Wang et al [22] reported that bio-lubricants should be considered to be an important factor on the tribological behavior of bone and titanium alloys. The extreme conditions of tests, used in this study, are far from being the case in vivo, however accidents may result and they could be an effective tool when choosing the appropriate material for the specific implant.…”
Section: Introductionmentioning
confidence: 99%
“…At the same time, it can be seen that the friction coefficient of the NT Ti alloy samples suddenly decreases during the period of 4–5 min, and then there is an obvious fluctuation. Some literatures show that even under lubrication conditions, adhesion wear of titanium alloys can occur [48], which is related to the contact state of friction pair materials in the initial stage of friction. With the progress of the experiment, a certain amount of debris is produced on the surface of the titanium alloy matrix, which plays the role of lubrication, isolation and support together with the liquid medium.…”
Section: Resultsmentioning
confidence: 99%