2023
DOI: 10.1111/pace.14712
|View full text |Cite
|
Sign up to set email alerts
|

TriGuard Embolic Protection Device in percutaneous cardiac interventions with intracavitary cardiac thrombosis: A case series

Abstract: Embolic cerebral protection devices are not routinely used in clinical practice during electrophysiological interventions. We report a case series of patients with intracardiac thrombosis undergoing a percutaneous left atrial appendage (LAA) closure and a ventricular tachycardia (VT) catheter ablation supported by TriGuard 3 Cerebral Embolic Protection Device.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 18 publications
0
1
0
Order By: Relevance
“…A partial umbrella delivery of a LAmbre 24/30 mm was done in front of LAA ostium and the whole system was advanced up to the point immediately before thrombus in LAA superior lobe [ 34 ] Kaczmarek 2021 Watchman = 2 Watchman FLX = 2 ACP = 13 N/A N/A N/A 17 TEE and fluoroscopy No LAA angiography in 8 cases. 5 cases underwent LAA angiographies with gentle hand contrast injections through pigtail catheters [ 35 ] Marcon 2023 Watchman FLX = 6 N/A N/A 6 6 TEE or ICE “One shot technique” and a stepwise approach based on continuous ICE monitoring (It consists of ICE guided trans-septal puncture and guidewire advancement within the left superior pulmonary vein; exchange with long delivery sheath; trans-septal crossing with the ICE probe, reaching the point allowing the best LAA view (usually at the LSPV ostium); LAA occluder sizing based on landing zone measurement and LAA occluder deploy under ICE monitoring) [ 36 ] Cruz-Gonzalez 2017 Lambre = 1 N/A N/A 1 1 TEE and fluoroscopy Partial deployment of device at the LAA ostium and it was advanced under simultaneous counterclockwise rotation [ 37 ] Cammalleri 2016 ACP = 1 N/A N/A 1 1 TEE Standard endocardial LAAC procedure [ 38 ] Pak 2013 ACP = 1 N/A N/A N/A 1 TEE Transseptal sheath was advanced into LSPV ...…”
Section: Resultsmentioning
confidence: 99%
“…A partial umbrella delivery of a LAmbre 24/30 mm was done in front of LAA ostium and the whole system was advanced up to the point immediately before thrombus in LAA superior lobe [ 34 ] Kaczmarek 2021 Watchman = 2 Watchman FLX = 2 ACP = 13 N/A N/A N/A 17 TEE and fluoroscopy No LAA angiography in 8 cases. 5 cases underwent LAA angiographies with gentle hand contrast injections through pigtail catheters [ 35 ] Marcon 2023 Watchman FLX = 6 N/A N/A 6 6 TEE or ICE “One shot technique” and a stepwise approach based on continuous ICE monitoring (It consists of ICE guided trans-septal puncture and guidewire advancement within the left superior pulmonary vein; exchange with long delivery sheath; trans-septal crossing with the ICE probe, reaching the point allowing the best LAA view (usually at the LSPV ostium); LAA occluder sizing based on landing zone measurement and LAA occluder deploy under ICE monitoring) [ 36 ] Cruz-Gonzalez 2017 Lambre = 1 N/A N/A 1 1 TEE and fluoroscopy Partial deployment of device at the LAA ostium and it was advanced under simultaneous counterclockwise rotation [ 37 ] Cammalleri 2016 ACP = 1 N/A N/A 1 1 TEE Standard endocardial LAAC procedure [ 38 ] Pak 2013 ACP = 1 N/A N/A N/A 1 TEE Transseptal sheath was advanced into LSPV ...…”
Section: Resultsmentioning
confidence: 99%