2017
DOI: 10.5194/essd-9-15-2017
|View full text |Cite
|
Sign up to set email alerts
|

Tropospheric water vapour isotopologue data (H<sub>2</sub><sup>16</sup>O, H<sub>2</sub><sup>18</sup>O, and HD<sup>16</sup>O) as obtained from NDACC/FTIR solar absorption spectra

Abstract: Abstract. We report on the ground-based FTIR (Fourier transform infrared) tropospheric water vapour isotopologue remote sensing data that have been recently made available via the database of NDACC (Network for the Detection of Atmospheric Composition Change; ftp://ftp.cpc.ncep.noaa.gov/ndacc/MUSICA/) and via doi:10.5281/zenodo.48902. Currently, data are available for 12 globally distributed stations. They have been centrally retrieved and quality-filtered in the framework of the MUSICA project (MUlti-platform… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
43
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
2
1

Relationship

3
6

Authors

Journals

citations
Cited by 39 publications
(43 citation statements)
references
References 25 publications
0
43
0
Order By: Relevance
“…Instruments along the x axis (top) are X while instruments along the y axis (side) are Y in Eqs. (1) and (2). A high-resolution version of this table can be found in Table S2.…”
Section: Pal To Ridge Lab Partial Column Comparisonsmentioning
confidence: 99%
“…Instruments along the x axis (top) are X while instruments along the y axis (side) are Y in Eqs. (1) and (2). A high-resolution version of this table can be found in Table S2.…”
Section: Pal To Ridge Lab Partial Column Comparisonsmentioning
confidence: 99%
“…TES is an FTIR aboard Aura that observes emitted radiance between 650 and 3050 cm −1 spectral resolution of 0.10 cm −1 when observing in nadir mode and 0.025 cm −1 in limbviewing mode (Beer et al, 2001). Limb-scanning measurements were performed only until May 2005.…”
Section: Tesmentioning
confidence: 99%
“…The CANDAC Bruker IFS 125HR is a Fourier transform infrared spectrometer (FTIR) that is part of the Network for the Detection of Atmospheric Composition Change (NDACC, www.ndacc.org). The Bruker 125HR was deployed at the Polar Environmental Atmosphere Research Laboratory (PEARL) Ridge Lab (86.4 • W, 80.1 • N; Fogal et al, 2013) in 2006 (Batchelor et al, 2009). The PEARL Ridge Lab is 610 m above sea level, 15 km away from EWS (which is 10 m above sea level).…”
Section: Water Vapour and Hdo Measurementsmentioning
confidence: 99%