2015 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA) 2015
DOI: 10.1109/pepqa.2015.7168238
|View full text |Cite
|
Sign up to set email alerts
|

Two-phase active power filter direct current control with capacitor voltages estimation and balance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 11 publications
0
4
0
1
Order By: Relevance
“…For instance, a five-level shunt APF configuration using predictive controllers is devised for compensation of current unbalance and harmonics in [29]. The same topology is employed for reactive power compensation in [30], presenting an innovative DC bus capacitor voltage balancing strategy that requires a reduced number of sensors. In addition, reactive power control, harmonic mitigation, and balancing of currents in 2Φ3w grids is also presented in [31] and [32] by means of a back-to-back converter that uses predictive directive current control.…”
Section: A Comprehensive Literature Reviewmentioning
confidence: 99%
“…For instance, a five-level shunt APF configuration using predictive controllers is devised for compensation of current unbalance and harmonics in [29]. The same topology is employed for reactive power compensation in [30], presenting an innovative DC bus capacitor voltage balancing strategy that requires a reduced number of sensors. In addition, reactive power control, harmonic mitigation, and balancing of currents in 2Φ3w grids is also presented in [31] and [32] by means of a back-to-back converter that uses predictive directive current control.…”
Section: A Comprehensive Literature Reviewmentioning
confidence: 99%
“…El Filtro activo de potencia (APF) para aplicaciones monofásicas y trifásicas se encuentra ampliamente reportada en la literatura técnica en [1], [2], [3], [4], pero hay una falta de documentos que aborden aplicaciones en sistemas bifásicos. Entre los pocos trabajos sobre sistemas bifásicos están [5], [6], donde los autores han propuesto el uso de dos convertidores de 5 niveles para la compensación de los armónicos de corriente entre dos fases de un sistema trifásico como se muestra en la Fig. 2.…”
Section: Filtros Activos De Potencia En Sistemas Bifásicosunclassified
“…The authors of [7] formulated alternative methods through the p-q theory focusing on the control of 2Φ3W converters driven with the overlap of two simultaneous operation modes to further mitigate neutral currents. The authors of [8] propose active power conditioning in 2Φ3W circuits based on the exchange of powers between existing phases, using the DC link of multilevel converters. All of these works use an angle displacement of 120 • between the line voltages.…”
Section: Introductionmentioning
confidence: 99%