2020
DOI: 10.1109/jestpe.2019.2936145
|View full text |Cite
|
Sign up to set email alerts
|

Two-Stage Isolated Bidirectional DC–AC Converters With Three-Port Converters and Two DC Buses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
12
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 45 publications
(13 citation statements)
references
References 24 publications
0
12
0
1
Order By: Relevance
“…A method for deriving non‐isolated TPC from primary converters for multiple input/output is presented in reference [6]. Isolated TPCs with two DC buses and an AC port at the output are demonstrated in references [7] and [8]. A coupled inductor based high gain converter with a soft switching feature is presented in reference [9] and a TPC is presented in reference [10].…”
Section: Introductionmentioning
confidence: 99%
“…A method for deriving non‐isolated TPC from primary converters for multiple input/output is presented in reference [6]. Isolated TPCs with two DC buses and an AC port at the output are demonstrated in references [7] and [8]. A coupled inductor based high gain converter with a soft switching feature is presented in reference [9] and a TPC is presented in reference [10].…”
Section: Introductionmentioning
confidence: 99%
“…Bu bağlamda, bazı çalışmalar YFT'nin birincil tarafında bağlantı noktası artışını ele alırken bazıları ise YFT'nin ikincil tarafında bağlantı noktası artışı üzerine odaklanmıştır. [28] çalışmasında, ikincil taraf tam köprü doğrultucu iki DA çıkış portu elde etmek için ortak bir toprak ve farklı pozitif terminaller ile iki ayrı anahtarlama koluna bölünmüştür. Azaltılmış anahtarlama yapısına sahip entegre dönüştürücüler içerisinde interleaved yapılar ön plana çıkmaktadır.…”
Section: Introductionunclassified
“…In such systems, the main challenges are mostly associated with providing voltage step-up from a low-voltage energy source, like a battery or to provide galvanic isolation as a safety measure, such as required in EV charging. Typically, to achieve demanded functionality, a two-stage power electronic system is used (Figure 1a) [29][30][31][32][33]. Variable input DC voltage is first stabilized at a DC-link capacitor by a DC-DC converter that often features a high-frequency (HF) transformer (HFT) for both voltages matching and the galvanic isolation.…”
Section: Introductionmentioning
confidence: 99%
“…It is then followed by an inverter stage that converts the stabilized DC voltage of the appropriate level into the AC voltage. These systems offer a good regulation range and are widely used in practical applications [29][30][31][32][33][34].…”
Section: Introductionmentioning
confidence: 99%