2008
DOI: 10.1111/j.1751-3928.2008.00052.x
|View full text |Cite
|
Sign up to set email alerts
|

U‐Pb Age Determination for Seven Standard Zircons using Inductively Coupled Plasma–Mass Spectrometry Coupled with Frequency Quintupled Nd‐YAG (λ = 213 nm) Laser Ablation System: Comparison with LA‐ICP‐MS Zircon Analyses with a NIST Glass Reference Material

Abstract: This paper evaluates the analytical precision, accuracy and long-term reliability of the U-Pb age data obtained using inductively coupled plasma -mass spectrometry (ICP-MS) with a frequency quintupled Nd-YAG ( = 213nm) laser ablation system. The U-Pb age data for seven standard zircons of various ages, from 28 Ma to 2400 Ma (FCT, SL13, 91500, AS3, FC1, QGNG and PMA7) were obtained with an ablation pit size of 30 m d iameter. For 207 Pb/ 206 Pb ratio measurement, the mean isotopic ratio obtained on National In… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
57
0
2

Year Published

2008
2008
2024
2024

Publication Types

Select...
8
2

Relationship

3
7

Authors

Journals

citations
Cited by 105 publications
(60 citation statements)
references
References 45 publications
1
57
0
2
Order By: Relevance
“…Abbreviations: Gp., Group; Fm., Formation. ml/min) was added to the He carrier gas. Detailed procedure and analytical precision are described in Orihashi et al (2008).…”
Section: Samples and Methodsmentioning
confidence: 99%
“…Abbreviations: Gp., Group; Fm., Formation. ml/min) was added to the He carrier gas. Detailed procedure and analytical precision are described in Orihashi et al (2008).…”
Section: Samples and Methodsmentioning
confidence: 99%
“…To achieve this, charcoal filters for the removal of Hg in Ar gas (Hirata and Nesbitt, 1995;Hirata et al, 2005) and the signal smoothing device (Tunheng and Hirata, 2004) were components of our LA-ICP-MS system (Orihashi et al, 2008). Moreover, a femtosecond laser ablation system was employed to reduce the elemental fractionation during the laser ablation (Hirata and Kon, 2008).…”
Section: Zircon U-pb Datingmentioning
confidence: 99%
“…В Токийском технологическом институте (Япо-ния) преимущества offset-оптики [10,11] реализо-вывали с 2000 г. на стандартных серийных ИСП-масс-спектрометрах VG PQ2/S/Omega [35][36][37] и VG PQ3S [38] (производства Thermo Elemental или Thermo Electron) путем соответствующей модификации их штатной осесимметричной оптики. Для этого в центре последней [3] вместо фотонейтралостопа устанавливали группу из 5 параллельных отклоня-ющих пластин (названных chicane-lens), снабжен-ных, подобно [10,11], дугообразно смещенными от главной оси проходными отверстиями для ио-нов (см.…”
Section: японский вариант оптикиunclassified