2017
DOI: 10.24843/bf.2017.v18.i01.p05
|View full text |Cite
|
Sign up to set email alerts
|

Uji Kelayakan Pesawat Sinar-X Terhadap Proyeksi Pa (Postero-Anterior) Dan Lat (Lateral) Pada Teknik Pemeriksaan Foto Thorax

Abstract: Research has been conducted to determine feasibility test of the X-ray planePA and LAT projections on chest x-ray techniques. The study using a water phantom object as a substitute for patients with variations in interval distance ofthe  100-180 cm. Measurement of radiation dose X-rays performed five repetitions , measurable doses had be read on the device electrometer. Exposition factors to the PA projection using a tube voltage of 75 kV, current and time of 3,2 mAs, the irradiation field areaof (30 x 30) cm2… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
1
0
3

Year Published

2020
2020
2023
2023

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 1 publication
0
1
0
3
Order By: Relevance
“…Sinar-X yang dipancarkan dari tabung inersia diarahkan ke bagian tubuh yang akan didiagnosis. Sinar-X akan menembus dan melewati bagian tubuh, kemudian ditangkap oleh film sehingga terbentuk citra bagian tubuh yang di eksposi [5]. Pesawat sinar-X terdiri dari control panel, transformator, generator dan tabung sinar-X.…”
Section: Landasan Teoriunclassified
“…Sinar-X yang dipancarkan dari tabung inersia diarahkan ke bagian tubuh yang akan didiagnosis. Sinar-X akan menembus dan melewati bagian tubuh, kemudian ditangkap oleh film sehingga terbentuk citra bagian tubuh yang di eksposi [5]. Pesawat sinar-X terdiri dari control panel, transformator, generator dan tabung sinar-X.…”
Section: Landasan Teoriunclassified
“…Bahan yang digunakan dalam penelitian ini yaitu seperangkat sistem Digital Radiography merk Toshiba, software imageJ, koin aluminium dengan ketebalan 8,25 mm, 16,5 mm, 24,75 mm, 33 mm, 41,25 mm, 49,5 mm dan 57,75 mm. Parameter pengukuran yang diamati adalah variasi tegangan 60, 65, 70 dan 75 kVp dengan masing-masing variasi arus sebesar 16, 20 dan 25 mAs [1], [6], [10], [11] terhadap masing-masing ketebalan koin.…”
Section: Bahan Dan Metodeunclassified
“…Computed Tomography Scan (CT scan) merupakan salah satu alat yang digunakan untuk mendiagnosa penyakit pada bagian dalam tubuh manusia dengan memanfaatkan sinar-X. Pemanfaatan sinar-X di bidang kedokteran nuklir merupakan salah satu cara meningkatkan kesehatan masyarakat [2]. CT scan digunakan untuk mengetahui ada atau tidaknya suatu kelainan pada tubuh.…”
Section: Pendahuluanunclassified