2014
DOI: 10.15554/pcij.09012014.48.62
|View full text |Cite
|
Sign up to set email alerts
|

Ultra-high-performance concrete connections for precast concrete bridge decks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
84
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 83 publications
(88 citation statements)
references
References 0 publications
2
84
0
2
Order By: Relevance
“…This specimen configuration allows determining accurately the contribution of UHPFRC cover on an isolated portion of lap splices in tension, which could represent a thin UHPFRC layer used for strengthening poorly detailed lap splices [17], or a UHPFRC lap splice joint between precast elements [22].…”
Section: Test Specimens and Test Parametersmentioning
confidence: 99%
See 2 more Smart Citations
“…This specimen configuration allows determining accurately the contribution of UHPFRC cover on an isolated portion of lap splices in tension, which could represent a thin UHPFRC layer used for strengthening poorly detailed lap splices [17], or a UHPFRC lap splice joint between precast elements [22].…”
Section: Test Specimens and Test Parametersmentioning
confidence: 99%
“…It has been shown that the use of UHPFRC in the lap splice region allowed to: (1) strengthen seismically existing bridge piers with poor detailing at their bottom [13][14][15][16][17][18][19], (2) significantly reduce the joint lengths between precast-slab lengths for building [8,20] and bridges construction [21,22], (3) create an alternative proposal for moment-resisting frames (beam-column) in precast building with innovative joint connection [23].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, static response modeling of the joint was performed through finite element method (FEM) analysis [7]. Various reinforcement shapes and types as well as various lapped splice constructions, including those using U-bars, were used as variables in the evaluation of the structural performance [3,[8][9][10]. In addition, strength tests on connection systems were performed using the flange combinations of the Bulb-Tee girder, with analysis of crack propagation and system strength [11].…”
Section: Introductionmentioning
confidence: 99%
“…Three types of joint reinforcement shapes were suggested using the shape of a joint, the type and arrangement of reinforcements, and a lap splice as the variables, and a performance test was performed [10,11]. Moreover, the longitudinal and transverse performances of a U-bar precast joint were verified [12].…”
Section: Introductionmentioning
confidence: 99%