2014
DOI: 10.1016/j.optcom.2013.11.011
|View full text |Cite
|
Sign up to set email alerts
|

Ultra reliable infrared absorption water vapor detection through the all-electronic feedback stabilization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 14 publications
0
4
0
Order By: Relevance
“…Single-beam systems have been proposed for water vapor sensing for years, but light power drift has a strong impact on detection system reliability. Many works have been performed around a singlebeam optical structure for suppressing the light power drift as mentioned in [6,17], whose advantages and disadvantages have been discussed compared with the single-beam method proposed in this paper. A dual-beam difference system can suppress the influence from light power drift in common mode, but some factors, such as thermal fluctuations, will make changes in reference and signal beams different from each other and cause measurement error.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Single-beam systems have been proposed for water vapor sensing for years, but light power drift has a strong impact on detection system reliability. Many works have been performed around a singlebeam optical structure for suppressing the light power drift as mentioned in [6,17], whose advantages and disadvantages have been discussed compared with the single-beam method proposed in this paper. A dual-beam difference system can suppress the influence from light power drift in common mode, but some factors, such as thermal fluctuations, will make changes in reference and signal beams different from each other and cause measurement error.…”
Section: Resultsmentioning
confidence: 99%
“…This method can increase the signal-to-noise ratio but perform poorly in terms of power fluctuation suppression. Then a singlebeam balanced radiometric detection (BRD) system with all-electronic feedback stabilization is proposed for high-reliability water vapor detection, which is insensitive to the fluctuation of transmission loss of light [6]. Later, a technique using automatic photoelectric conversion gain control is proposed to promote the power fluctuation suppression characteristics in a single-beam system [17].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations