Ultrafast Flow Quantification With Segmented k-Space Magnetic Resonance Phase Velocity Mapping

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
1

Year Published

2002
2002
2013
2013

Publication Types

Select...
5
4

Relationship

3
6

Authors

Journals

citations
Cited by 16 publications
(14 citation statements)
references
References 31 publications
0
13
0
1
Order By: Relevance
“…This is very important considering the large difference in the number of slices necessary to image the region of interest in both models (20 transverse vs. 3 coronal in the tube; 36 transverse vs. 3 coronal in the TCPC). Currently, the scan time for ECGgated acquisitions of three slices with all velocity components is 3-10 min depending on the degree of k-space segmentation [37,38]; the scan time would be 15-30 min for 20 slices and more than 35 min for 36 slices, making the clinical implementation of the method imprac tical and unappealing.…”
Section: Discussionmentioning
confidence: 99%
“…This is very important considering the large difference in the number of slices necessary to image the region of interest in both models (20 transverse vs. 3 coronal in the tube; 36 transverse vs. 3 coronal in the TCPC). Currently, the scan time for ECGgated acquisitions of three slices with all velocity components is 3-10 min depending on the degree of k-space segmentation [37,38]; the scan time would be 15-30 min for 20 slices and more than 35 min for 36 slices, making the clinical implementation of the method imprac tical and unappealing.…”
Section: Discussionmentioning
confidence: 99%
“…Flussquantifizierungen mit Hilfe segmentierter atemangehaltener Phasenkontrast-Sequenzen stimmen sowohl mit 7 als auch mit 9 "number of views per segment" (NVS) und Anwendung von Phase sharing gut mit den Ergebnissen der nicht-segmentierten Flussmessung bei freier Atmung überein [24,34]. Die Rekonstruktion von mehr als 10 bis 16 Cine-Frames pro Herzzyklus verbesserte die Genauigkeit einer Phasenkontrast-Messung mit 8 k-Raum Zeilen pro Segment und einstellbarem Grad des Viewsharing nicht [14].…”
Section: Ergebnisseunclassified
“…If velocity-encoding gradients are added to the regular sequence, the flow velocity can be measured rapidly. Systematic in vitro [65,66] and in vivo [67] studies have shown that segmented k-space MR PVM is very accurate in quantifying flow from through-plane velocity measurements, under a variety imaging parameters. The in vitro study involved flow quantification from throughplane velocity data in straight tubes, under a vari ety of steady and pulsatile flow conditions.…”
Section: Rapid Magnetic Resonance Phase Velocity Mappingmentioning
confidence: 99%
“…The in vitro study involved flow quantification from throughplane velocity data in straight tubes, under a vari ety of steady and pulsatile flow conditions. The effect of the number of k-space lines per segment was studied by examining the unsegmented se quence and three segmented k-space schemes, with five [65], seven [66] and nine [65] k-space lines per segment. Results showed that both segmented se quences provided very accurate flow quantifica tion (errors < 5%) under both steady and pulsatile flow conditions (p-value 0.05).…”
Section: Rapid Magnetic Resonance Phase Velocity Mappingmentioning
confidence: 99%